《哈里伯顿内部材料.ppt》由会员分享,可在线阅读,更多相关《哈里伯顿内部材料.ppt(22页珍藏版)》请在三一办公上搜索。
1、ROC Permanent Monitoring Systems,WellDynamics:Transforming Reservoirs with SmartWell System Technology,Our missionTo be the premier provider of intelligent completion technology,creating value for our customers by delivering fit-for-purpose,innovative and reliable solutions for zonal isolation and f
2、low control,reservoir monitoring,fiber optic and surface digital infrastructure,Flow Control,Fiber Optics,Permanent Monitoring,Digital Infrastructure,Permanent Monitoring:Applications,Optimized ProductionAnalyze pressure lossesAccelerate productionObtain data from unplanned shutdownsMonitor formatio
3、n damage through well transientsOptimize artificial liftOptimize sand control and stimulation,Reservoir ManagementImprove understanding of the reservoir and quality of reservoir descriptionPredict future production/recovery for various development strategiesImprove reserves calculation and optimize
4、production of recoverable reservesReceive early data on actual vs predicted performance,Permanent Monitoring Components,Track Record&Reliability,Permanent Monitoring Reliability R(60),ROC Environmental Operating Envelope,ROC-H 10K 150C9381-6010,ROC-H 16K 177CTBD,ROC-H 20K 200C9381-6012,ROC-H 25K 200
5、C9381-6013,ROC-H 30K 200CTBD,ROC-H,ROC-150 Series,ROC-175 Series,ROC-200 Series,ROC Environmental Operating Envelope,ROC-H 10K 150C9381-6010,ROC-H 16K 177CTBD,ROC-H 20K 200C9381-6012,ROC-H 25K 200C9381-6013,ROC-H 30K 200CTBD,ROC-H,ROC-300,ROC-350,ROC-400,ROC-15010K,ROC-17516K,ROC-17520K,ROC-17525K,R
6、OC-20025K,ROC-20020K,ROC-20030K,ROC Gauge Variants,ROC dualP/T sensor,ROC dual P/T sensor plus feedthrough,ROC fully redundantP/T sensor plus feedthrough,ROC singleP/T sensor,plus feedthrough,ROC singleP/T sensor,ROC fully redundantP/T sensor,Note:Fully redundant configurations contain dual electron
7、ics and dual sensors ported to a single pressure port,ROC-Standard Gauge Configurations,ROC Permanent Downhole Gauges,Cable termination(field-pressure testable),PCB/hybrid,Mechanical arrangement,including seals,Pressure/temperature quartz transducer,HPHT Environments:ROC Permanent Downhole Gauge,Qua
8、rtz sensor-based designHigh accuracy(0.02%FS)High resolution(90%5 yrs 180C,3”,ROC Hybrid Advantages,Long-term reliability at extreme temperatures Excellent heat dissipation over traditional downhole electronicsImproved thermal shock resistance Improved physical shock and vibration resistance Compact
9、 size,Qualification Testing Completed,Electronic Circuit TestingVerified functionality from 0C to 220CTelemetry PerformanceDetermined telemetry performance at 35,000ft cable lengthNoise Tolerance TestingConfirmed telemetry performance in high noise environmentHALT TestingLifetime testing including c
10、ombined environment testingWeld and Seal TestingTesting of seal performance at elevated pressure and temperatureQALT TestingDetermine lifetime estimates as a function of temperature,ROC Lifetime Estimates,Gauge Mandrels,Slimline designMachined from solid billetNo welded partsUltrasonic wall thicknes
11、s testAPI 5CT standardBody burst testGauge mandrel pressure testMultiple sealsFull component protectionLine bypass slots,Single Gauge Mandrel,Dual Gauge Mandrel,Triple Gauge Mandrel,FloStream Venturi Flowmeter Mandrel,Tubing Encased Conductor(TEC),TEC(Tubing Encased Conductor)Alloy 825&Stainless Ste
12、elWall thickness:0.028”,0.035”&0.049”Up to 34,000 ftInsulator ratings:135C/275F,150C/302F,200C/392FHeavier wall options preferred Reduce handling risk at tubing hanger Higher pressure rating Better sealing Higher tensile strength Higher crush resistance,PurposeSupports and protects TEC/Control lines
13、 from axial and compressive loadsDesigned to suit the completionAvailable in all cast carbon steel or pressed steelIssues to Consider:Cast vs.Pressed SteelInterlocking designLower angle chamberLine configuration hanger terminationsTorque settingsInsulated sleevesRiser centralizers,Control Line Protectors,Digital Infrastructure,SmartWell Master supervisory applicationXPIO data acquisition and control unitSubsea interface cardsIWIS interface,SmartWell Master Application Screen,Subsea Interface Card,XPIO Data Acquisition and Control Unit,