【AS澳大利亚标准】AS NZS 1429.21998 Electric cables—Polymeric insulated Part 2 For working voltages .doc
《【AS澳大利亚标准】AS NZS 1429.21998 Electric cables—Polymeric insulated Part 2 For working voltages .doc》由会员分享,可在线阅读,更多相关《【AS澳大利亚标准】AS NZS 1429.21998 Electric cables—Polymeric insulated Part 2 For working voltages .doc(37页珍藏版)》请在三一办公上搜索。
1、AS/NZS 1429.2:1998Australian/New Zealand StandardElectric cables Polymeric insulatedPart 2: For working voltages above19/33 (36) kV up to and including76/132 (145) kVAS /NZS 1429.2:1998This Joint Australian/New Zealand S tandard was prepared by Joint Technical Commit tee EL/ 3, El ectric Wir es and
2、Cables. It was approved on behalf of the Council of St andards Australi a on 17 November 1997 and on behalf of the Council of S tandards New Zealand on 17 November 1997. It was publi shed on5 February 1998.The foll owing interests are represented on Commit tee EL /3: Australasian Railways Associati
3、onAustrali an Electrical and Electronic Manufacturers Associati onDepartment of Defence, Australi aEl ectrical regulatory authoriti esEl ectricit y S upply Associated of AustraliaInstit ution of Engineers, Australi aMinistry of Commerce, New ZealandNew Zealand Electrical Contractors Associati onNew
4、Zealand Electrical and Electronic Manufacturers Federati onOffice of Energy, N.S.W.Testi ng interestsReview of Standards. To keep abreast of progress in industry, Joint Australian/ New Zealand Standards are subject to periodic review and are kept up to date by the issue of amendments or new editions
5、 as necessary. It is important therefore that Standards users ensure that they are in possession of the latest edition, and any amendments thereto.Full details of all Joint Standards and related publications will be found in the Standards Australia and Standards New Zealand Catalogue of Publications
6、; this information is supplemented each month by the magazines The Australian Standard and Standards New Zealand, which subscribing members receive, and which give details of new publications, new editions and amendments, and of withdrawn Standards.Suggestions for improvements to Joint Standards, ad
7、dressed to the head office of either Standards Australia or Standards New Zealand, are welcomed. Notification of any inaccuracy or ambiguity found in a Joint Australian/New Zealand Standard should be made without delay in order that the matter may be investigated and appropriate action taken.This St
8、andard was issued in draft form for comment as DR 97035.AS/NZS 1429.2:1998Australian/New Zealand StandardElectric cables Polymeric insulatedPart 2: For working voltages above19/33 (36) kV up to and including76/132 (145) kVFirst published as AS/NZS 1429.2:1998.PUBLI SHED JOINTLY BY:STANDARDS AUSTRALI
9、 A1 The Crescen t,Homeb ush NSW 214 0 Au strali aSTANDARDS NEW ZEALA NDLe vel 10 , Radi o New Zea la nd House,15 5 The Terrace,We lli ngt on 600 1 New Ze ala ndIS BN 0 7337 1722 533AS/N ZS 1429.2:1 998PREFACEThis Standard w as prepared by the Joint Standards A ustralia/Standards N ew Zealand Committ
10、ee EL/3, Electric Wires and Cables, to complement A S 1429.1 1993, Electric cables Polymeric insulated , Part 1: For working voltages 1.9/3.3(3.6) kV up to and including 19/33(36) kV.The objective of this Standard is to specify requirements for single-core cross-linked polyethyleneinsulatedcablesfor
11、 fixedinstallationsoperatingatvoltagesabove19/33(36) kV up to and including 76/132(145) kV.In the preparation of this Standard, consideration was given to the following publications and acknow ledgment is made of the assistance received:IEC229Tests on cable overs heaths w hich have a special protect
12、ive function and are applied by extrusion502Extruded solid dielectric insulated power cables for rated voltages fr om 1 kV up to30 kV840Tests for power cables w ith extruded insulation for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (U m = 170 kV )811Common test methods for insulating and s
13、heathing materials of electric cables (all parts)AE ICCS7Specifications for crosslinked polyethylene insulated shielded pow er cables rated69 through 138 kVThe nominal cross-sectional areas of the conductors specified herein are identical with the values specified in AS 1125, Conductors in insulated
14、 electric cables and flexible cords . Additional conductor sizes referenced are specified in IEC 228, Conductors of insulated cables . The dimensions for non-metallic sheath thicknesses are based on the values recommended in IEC 502. Certain tests and criteria in this Standard are more stringent tha
15、n those in IEC 840.One type of insulation compound is specified in this Standard, namely insulation comprising cross-linked polyethylene (X LPE).Although the Standard provides tables of insulation thicknesses and the necessary information to establish precisely the dimensions of the cable protective
16、 coverings, no cable dimension tables are provided owing to the variety of cable constructions that could affect such dimensions.The term s normative and informative have been used in this Standard to define the application of the appendix to w hich they apply. A norm ative appendix is an integral p
17、art of a Standard, w hereas an informative appendix is only for information and guidance.Statements expressed in mandatory term s in notes to tables and figures are deemed to be requirements of this Standard.CONTENTSPageSECTIO N 1 SCOPE A ND GE N ERA L1.1SCO PE . . . . . . . . . . . . . . . . . . .
18、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.2REFERENCED D O CUMEN TS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51.3DE FIN ITION S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5SECTIO N 2 CON STRUCTIO N2.1GE N ERA L . .
19、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.2OP ERATIN G V OL TAG ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82.3MAX IMU M CON DU CTO R TEMPERA TU RE . . . . . . . . . . . . . . . . . . . . . 82.4CON DU CTO RS . . . . . . .
20、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82.5CON DU CTO R SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82.6IN SUL A TION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.7EX TRUD ED IN SU LAT
21、 ION SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.8WA TER BLO CKIN G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102.9MOISTU RE BARRIER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102.10METAL SH EA TH . . . . . . . .
22、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102.11METAL LIC SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102.12BIN DE RS AN D BA RRIER TA PES . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112.13NO N -META LLIC SH EA TH . . . .