【AS澳大利亚标准】AS NZS 40262001 Electric cables—For underground residential distribution systems.doc
《【AS澳大利亚标准】AS NZS 40262001 Electric cables—For underground residential distribution systems.doc》由会员分享,可在线阅读,更多相关《【AS澳大利亚标准】AS NZS 40262001 Electric cables—For underground residential distribution systems.doc(32页珍藏版)》请在三一办公上搜索。
1、AS/NZS 4026:2001Licensed to UEA Electrical Pty Ltd on 06 Mar 2007. 1 user personal user licence only. Storage, distribution or use on network prohibited.AS/NZS 4026Australian/New Zealand StandardElectric cablesFor underground residential distribution systemsLicensed to UEA Electrical Pty Ltd on 06 M
2、ar 2007. 1 user personal user licence only. Storage, distribution or use on network prohibited.AS/NZS 4026:2001This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee EL-003, Electric Wires and Cables. It was approved on behalf of the Council of Standards Australia on 18
3、 April 2001 and on behalf of the Council of Standards New Zealand on 27 April 2001. It was published on 28 May 2001.The following interests are represented on Committee EL-003:Australasian Railway AssociationAustralian Electrical and Electronic Manufacturers AssociationAustralian Industry GroupDepar
4、tment of Defence, AustraliaDepartment of Mineral Resources, N.S.W.Electrical Contractors Association of New ZealandElectricity Supply Association of AustraliaInstitution of Engineers, AustraliaMinistry of Commerce, New ZealandNational Electrical & Communications AssociationNew Zealand Manufacturers
5、FederationRegulatory Authorities (Electrical)Testing Interests (Australia)Keeping Standards up-to-dateStandards are living documents which reflect progress in science, technology and systems. To maintain their currency, all Standards are periodically reviewed, and new editions are published. Between
6、 editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current Standard, which should include any amendments which may have been published since the Standard was purchased.Detailed information about joint Australian/New Z
7、ealand Standards can be found by visiting the Standards Australia web site at .au or Standards New Zealand web site at www.standards.co.nz and looking up the relevant Standard in the on-line catalogue.Alternatively, both organizations publish an annual printed Catalogue with full details of all curr
8、ent Standards. For more frequent listings or notification of revisions, amendments and withdrawals, Standards Australia and Standards New Zealand offer a number of update options. For information about these services, users should contact their respective national Standards organization.We also welc
9、ome suggestions for improvement in our Standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or ambiguities. Please address your comments to the Chief Executive of either Standards Australia International or Standards New Zealand at the address shown on th
10、e back cover.This Standard was issued in draft form for comment as DR 98043.AS/NZS 4026:2001Licensed to UEA Electrical Pty Ltd on 06 Mar 2007. 1 user personal user licence only. Storage, distribution or use on network prohibited.Australian/New Zealand StandardElectric cablesFor underground residenti
11、al distribution systemsFirst published as AS 40261992.Jointly revised and designated AS/NZS 4026:2001.COPYRIGHT Standards Australia/Standards New ZealandAll rights are reserved. No part of this work may be reproduced or copied in any form or by any means, electronic or mechanical, including photocop
12、ying, without the written permission of the publisher.Jointly published by Standards Australia International Ltd, GPO Box 5420, Sydney, NSW 2001 and Standards New Zealand, Private Bag 2439, Wellington 6020ISBN 0 7337 3900 8Licensed to UEA Electrical Pty Ltd on 06 Mar 2007. 1 user personal user licen
13、ce only. Storage, distribution or use on network prohibited.PREFACEThis Standard was prepared by the Joint Standards Australia / Standards New Zealand Committee EL-003, Electric Wires and Cables, to supersede AS 40261992 and NZS/AS 4026-1992, Electric cables For underground residential distribution
14、systems. The Standard applies to a range of cables recommended for use by electricity distributors in underground residential distribution (URD) systems at working voltages of 0.6/1 (1.2) kV, 6.35/11 (12) kV and12.7/22 (24) kV.For reasons of standardization and rationalization, this Standard provide
15、s for the construction, dimensions and test requirements of only a limited range of cables.The requirements of this Standard are compatible with and complementary to those for the range of cables covered in AS/NZS 1429.1, AS 1026 and AS/NZS 5000.1.This Standard differs from the previous edition in t