UL Subject 1012(0501)1.doc
《UL Subject 1012(0501)1.doc》由会员分享,可在线阅读,更多相关《UL Subject 1012(0501)1.doc(10页珍藏版)》请在三一办公上搜索。
1、Subject 1012May 1, 2009SUMMARY OF TOPICSThe following changes in requirements to the Standard for Power Units Other Than Class 2, UL1012, are being proposed:1. New requirements for batteries with integral chargers2. New requirements for power units for installation in air-handling spacesSTP BALLOTS
2、& COMMENTS DUE: JUNE 15, 2009For your convenience in review, proposed additions to existing requirements are shown underlined andproposed deletions are shown lined-out.1. New requirements for batteries with integral chargersRATIONALEProposal submitted by: Kent Donohue, Underwriters LaboratoriesUL pr
3、oposes new requirements for batteries with integral chargers. The proposal clarifies requirements applicable to batteries with integral chargers, and includes new requirements applicable to units witha solar cell feature.PROPOSALRECHARGEABLE BATTERIES WITH INTEGRAL CHARGERS92 Scope92.1 These require
4、ments supplement and in some cases modify the requirements of Sections 7 61. These requirements apply to indoor use, household, and commercial rechargeable battery packs (RBPs)of the alternating current supplied type, solar cell supplied type, or combination supplied type.92.2 These requirements do
5、not apply to a rechargeable battery for recharging from a separable batterycharger. Requirements for this type of rechargeable battery are specified in the Standard for Householdand Commercial Batteries, UL 2054.92.3 These requirements do not apply to a rechargeable battery intended for use in unint
6、erruptible powersupply applications. Requirements for this type of rechargeable battery are specified in the Standard forUninterruptible Power Supply Equipment, UL 1778.SUBJECT 1012-2-MAY 1, 200992.4 These requirements do not apply to a rechargeable battery with an integral load, such as arechargeab
7、le night light, rechargeable flashlight, a rechargeable shaver, a rechargeable screwdriver, andthe like. Requirements for these types of products are specified in other Standards appropriate to theintended use.93 Glossary93.1 For the purpose of the requirements in Sections 92 98, the following defin
8、itions apply.93.2 ALTERNATING CURRENT SUPPLIED During recharge, the RBP is connected to a nominal120 or 240 V, 15 or 20 A branch circuit receptacle. The RBP may be either direct plug-in or cord- andplug-connected.93.3 COMBINATION SUPPLIED A direct plug-in or cord- and plug-connected RBP that also em
9、ploysa solar cell integral to the RBP enclosure. During recharge, the RBP receives energy from either analternating current supply, from sunlight, or from both sources.93.4 RECHARGEABLE BATTERY PACK (RBP) A unit with an enclosure housing a battery chargercircuit, a rechargeable battery, control circ
10、uitry, and a polarized output connector integral to theenclosure or terminating on an output cord. During recharge the energy source is via an alternatingcurrent supply, or a solar cell. During discharge the output is connected to the load equipment.93.5 SOLAR CELL A photovoltaic assembly that conve
11、rts sunlight directly into electricity.93.6 SOLAR CELL SUPPLIED During recharge, the RBP receives energy via a solar cell integral tothe RBP enclosure.94 General94.1 The RBP shall comply with the applicable requirements of Sections 7 61, modified by theconstruction and performance requirements for s
12、econdary battery packs specified in the Standard forHousehold and Commercial Batteries, UL 2054.95 Construction95.1 Enclosure95.1.1 Polymeric enclosure materials of a solar cell or combination supplied RBP shall comply with theultraviolet light exposure requirements of the Standard for Polymeric Mat
13、erial Use in ElectricalEquipment Evaluations, UL 746C.SUBJECT 1012-3-MAY 1, 200995.2 Battery95.2.1 A battery intended for installation and replacement by other than trained technicians shall employa rigid mechanical enclosure that complies with the enclosure construction and test requirements of the
14、Standard for Household and Commercial Batteries, UL 2054.95.2.2 A RBP with a battery intended for installation and replacement by other than trained techniciansshall:a) Be designed to prevent misaligment, reverse polarity, damage upon connection, andaccessiblity of uninsulated parts during use; andb
15、) Provide a battery securement means to prevent inadvertent disconnection or damage duringuse.95.3 RBPs with a lithium battery95.3.1 Compatibility between a lithium-ion battery and the charging system shall be verified anddocumented by the RBP manufacturer. Verification documentation shall include:a
16、) The battery manufacturers specifications noted in 95.3.2; andb) Failure modes and effects analysis determining that the battery manufacturers specificationsnoted in 95.3.2 are not exceeded.95.3.2 The RBP manufacturer shall address in the product design the following specifications from thelithium-
17、ion cell manufacturer:a) Rated charging current, charging voltage and cutoff current, with compliance verified in theRBP under normal and single fault conditions within the system;b) Rated discharge current/rate and endpoint voltage, with compliance verified in the RBPunder normal and single fault c
18、onditions within the system;c) Maximum charging current and charging voltage limit (established as part of the batteryabnormal charging test), with compliance verified in the RBP under double fault conditionswithin the system; andd) The upper and lower ambient temperature ranges for charging and dis
19、charging, withcompliance verified in the RBP.SUBJECT 1012-4-MAY 1, 200995.4 Supply connections95.4.1 The supply cord of a combination supplied RBP shall comply with the outdoor use requirements ofthe Standard for Cord Sets and Power Supply Cords, UL 817.95.4.2 Polymeric materials of the appliance in
20、let of a combination supplied RBP intended for use with adetachable power supply cord shall comply with the ultraviolet light exposure requirements of theStandard for Polymeric Material Use in Electrical Equipment Evaluations, UL 746C. The appliance inletshall also comply with the Standard for Attac
21、hment Plugs and Receptacles, UL 498.95.5 Solar cell protection95.5.1 Means for protecting the solar cell from reverse current shall be provided under normal and singlefault conditions, and the overall construction shall comply with the solar cell reverse current overload testof 96.3.96 Performance96
22、.1 Power input test96.1.1 The RBP shall comply with Section 40, Power Input Test, when tested in accordance with 96.1.2.96.1.2 Prior to the test, the RBP is to be discharged in accordance with 40.3 40.5. The RBP is to thenbe connected to the alternating current supply and, if the construction permit