【AS澳大利亚标准】AS 36752002 Conductors—Covered overhead— For working voltages 6.3511 (12) kV up to.doc
《【AS澳大利亚标准】AS 36752002 Conductors—Covered overhead— For working voltages 6.3511 (12) kV up to.doc》由会员分享,可在线阅读,更多相关《【AS澳大利亚标准】AS 36752002 Conductors—Covered overhead— For working voltages 6.3511 (12) kV up to.doc(41页珍藏版)》请在三一办公上搜索。
1、AS/NZS 3675:2002Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 02 Apr 2007AS/NZS 3675Australian/New Zealand StandardConductorsCovered overhead For working voltages6.35/11 (12) kV up to and including19/33 (36) kVAccessed by UNIVERSITY OF SOUTH AUSTRALIA on 02 Apr 2007 AS/NZS 3675:2002 This Joint Austra
2、lian/New Zealand Standard was prepared by Joint Technical Committee EL-003, Electric Wires and Cables. It was approved on behalf of the Council of Standards Australia on 7 May 2002 and on behalf of the Council of Standards New Zealand on 9 May 2002. It was published on 30 May 2002.The following are
3、represented on Committee EL-003:Australasian Railway AssociationAustralian Electrical and Electronic Manufacturers AssociationAustralian Industry GroupCanterbury Manufacturers Association New ZealandDepartment of Defence (Australia)Department of Mineral Resources, N.S.W.Electrical Contractors Associ
4、ation of New ZealandElectrical Regulatory Authorities CouncilElectricity Supply Association of AustraliaInstitution of Engineers, AustraliaMinistry of Economic Development (New Zealand)National Electrical and Communications AssociationKeeping Standards up-to-dateStandards are living documents which
5、reflect progress in science, technology and systems. To maintain their currency, all Standards are periodically reviewed, and new editions are published. Between editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a curre
6、nt Standard, which should include any amendments which may have been published since the Standard was purchased.Detailed information about joint Australian/New Zealand Standards can be found by visiting the Standards Australia web site at .au or Standards New Zealand web site at www.standards.co.nz
7、and looking up the relevant Standard in the on-line catalogue.Alternatively, both organizations publish an annual printed Catalogue with full details of all current Standards. For more frequent listings or notification of revisions, amendments and withdrawals, Standards Australia and Standards New Z
8、ealand offer a number of update options. For information about these services, users should contact their respective national Standards organization.We also welcome suggestions for improvement in our Standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or
9、 ambiguities. Please address your comments to the Chief Executive of either Standards Australia International or Standards New Zealand at the address shown on the back cover.This Standard was issued in draft form for comment as DR 00391.AS/NZS 3675:2002Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 02
10、 Apr 2007Australian/New Zealand StandardConductorsCovered overhead For working voltages6.35/11 (12) kV up to and including19/33 (36) kVOriginated as AS 36751993.Jointly revised and redesignated AS/NZS 3675:2002.COPYRIGHT Standards Australia/Standards New ZealandAll rights are reserved. No part of th
11、is work may be reproduced or copied in any form or by any means, electronic or mechanical, including photocopying, without the written permission of the publisher.Jointly published by Standards Australia International Ltd, GPO Box 5420, Sydney, NSW 2001 and Standards New Zealand, Private Bag 2439, W
12、ellington 6020ISBN 0 7337 4547 4Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 02 Apr 2007PREFACEThis Standard was prepared by the Joint Standards Australia/Standards New Zealand Committee EL-003, Electric Wires and Cables, to supersede AS 36751993 and NZS/AS 36751993, Conductors Covered overhead For
13、working voltages 6.35/11 up to and including 19/33 kV.The objective of this Standard is to provide the construction, dimensions and test requirements for overhead covered conductors intended for power distribution, operating at voltages 6.35/11 (12) kV up to and including 19/33 (36) kV. Lines constr
14、ucted with covered conductors are an alternative to overhead bare conductor construction and aerial bundled cables.A rationalized range of stranded circular aluminium alloy conductors only are specified in this Standard.This Standard differs from the previous edition in the following significant way
15、s:(a)The Standard has been published as a Joint Australian/New Zealand Standard.(b)The requirements of the covering materials have been referred to AS/NZS 3808. (c)The 20 mm2 conductor size in the CC type has been deleted.(d)A 40 mm2 conductor size in the CCT type has been added.The terms normative
16、and informative have been used in this Standard to define the application of the appendix to which they apply. A normative appendix is an integral part of a Standard, whereas an informative appendix is only for information and guidance.9AS/NZS 3675:2002Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 02
17、 Apr 2007CONTENTSPageSECTION 1 SCOPE AND GENERAL1.1SCOPE. 41.2REFERENCED DOCUMENTS. 41.3DEFINITIONS. 51.4VOLTAGE DESIGNATION . 51.5MAXIMUM CONDUCTOR TEMPERATURE . 6SECTION 2 CONSTRUCTION2.1CONDUCTORS . 72.2COVERING. 72.3WATER BLOCKING . 72.4IDENTIFICATION. 82.5PREPARATION FOR DELIVERY . 82.6MARKING
18、OF DRUMS . 8SECTION 3 TESTS3.1ROUTINE TESTS . 113.2SAMPLE TESTS . 113.3TYPE TESTS. 11APPENDICESAAPPLICATION GUIDE . 13BPURCHASING GUIDELINES . 14CINTERSTRAND CONDUCTIVITY TEST . 15DSTATIC WATER BLOCKING TEST . 16EDYNAMIC WATER BLOCKING TEST . 19FSTRIPPING TEST . 21GADHESION TEST. 23HUV WEATHERING TE
19、ST . 25IDRIPPING TEST . 27JA GUIDE TO SELECTION OF COVERED CONDUCTORS . 29Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 02 Apr 2007STANDARDS AUSTRALIA/STANDARDS NEW ZEALANDAustralian/New Zealand StandardConductorsCovered overhead For working voltages6.35/11 (12) kV up to and including19/33 (36) kVS E