最新SwanGanz导管应用技巧与临床解读课件幻灯pptPPT文档.ppt
《最新SwanGanz导管应用技巧与临床解读课件幻灯pptPPT文档.ppt》由会员分享,可在线阅读,更多相关《最新SwanGanz导管应用技巧与临床解读课件幻灯pptPPT文档.ppt(47页珍藏版)》请在三一办公上搜索。
1、1967年加州大学洛杉矶分院Dr.Swan 由 顺着洋流飘回港湾的帆船,联想到带气囊 的心脏导管可以随血流在心脏内向前漂移。1970年Swan与Ganz合作研制了顶端带气囊的血流导向肺动脉漂浮导管(Balloon-tip flow-directed Catheter),并应用于临床。,Swan HJC and Ganz W.Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter.N Eng J Med 1970;283:447,Swan-Ganz导管,Swan-Ganz,Sw
2、an-Ganz Catheter_CuiNa,2010-3-28,Swan-Ganz,CVP/Proximal Infusion Lumen Hub,PA/Distal Lumen Hub,Balloon Inflation valve,Thermistor Connector,Balloon,Thermistor,Backform,SVO2 Optical Connector,Thermocouple wire Connector,RA/Proximal Injection Lumen Hub,Thermocouple wire on the surface of the catheter,
3、Bands,Swan-Ganz,PVC 聚氯乙烯材料,导管直径“French”,以不同颜色标示:,硬度“shore”,临床“触觉”及“扭结”辐射透不过染料,X 光下可见,4F-红色/粉红;5F-白色;6F-蓝色;7&8F-黄色,导管长度:成人一般为110cm,儿科为60-75cm,Swan-Ganz,临床应用技巧,Swan-Ganz,置管,监测数据解读,2010-3-28,Swan-Ganz Catheter CuiNa,测量,左心与右心,氧供与氧耗,穿刺路径:右颈内静脉最为常用,注意事项:床旁备有除颤器和利多卡因、肾上腺素等急救药品 可靠静脉通路;,Sedinger穿刺法 将导管鞘套在静脉扩
4、张器外,通过导丝送入,退出导丝及静脉扩张器后即可通过导管鞘插入Swan-Ganz导管。(成人7号,小儿5号),无菌操作,Swan-Ganz 置管,准备好穿刺针、导丝、扩张器、外套管、Swan-Ganz导管、压力传感器及冲洗装置等,PAC外套上保护鞘,将肺动脉腔及CVP腔用盐水冲注,与标定好的换能器相连,注1.5ml气体检查气囊是否匀称,Swan-Ganz 置管,Swan-Ganz 置管,Swan-Ganz 置管,Swan-Ganz 置管,Swan-Ganz 置管,Swan-Ganz Insertion,Swan-Ganz 置管,Swan-Ganz 置管,肺区的概念,3区,2区,1区,1区,2区
5、,3区,Swan-Ganz 置管,临床应用技巧,Swan-Ganz,置管,监测数据解读,2010-3-28,Swan-Ganz Catheter CuiNa,测量,左心与右心,氧供与氧耗,实际测量的关键环节,“通畅”,Fast Flush Test(Square wave Test),Swan-Ganz 测量,“调零”,“衰减”,压力传感器隔膜前端液体平面 右心房水平,腋中线第四肋间隙,收缩压变低舒张压增高,Assumptions of TD CO Determinations,Forward Blood FlowAdequate Mixing of Blood and InjectateSt
6、eady pulmonary artery baseline temperature,Swan-Ganz 测量,Intermittent Bolus Thermodilution,Swan-Ganz 测量,Intermittent CO Measurements Technical Issues,Smooth steady injectionAppropriate volume of injectateTiming of injectateAveraging strategyAppropriate computation constant,Swan-Ganz 测量,8 am CO/CI 6.0
7、/3.04 pm CO/CI 3.6/1.8,Room injectate.bag on monitor and warmer than measured injectate,1 degree C Room temp=7.7%error1 degree C Iced temp=2.7%error,Swan-Ganz 测量,What is the cause of the low CO?,Continuous Cardiac Output,Swan-Ganz 测量,CCO Modified Swan-Ganz Catheter,Swan-Ganz 测量,2010-3-28,Swan-Ganz C
8、atheter CuiNa,Continuous Cardiac Output,Swan-Ganz 测量,2010-3-28,Swan-Ganz Catheter CuiNa,临床应用技巧,Swan-Ganz,置管,监测数据解读,2010-3-28,Swan-Ganz Catheter CuiNa,测量,左心与右心,氧供与氧耗,适应症,绝对禁忌症相对禁忌症,血流动力学监测的目的,评价并维持机体的氧供需平衡,避免组织缺氧,协助诊断,确定高危人群指导治疗,评估患者预后,Swan-Ganz 数据解读,Oxygen Exchange,Oxygen Delivery,Oxygen Utilization
9、,Swan-Ganz 数据解读,Swan-Ganz 数据解读,2010-3-28,Swan-Ganz Catheter CuiNa,Oxygen Exchange,Swan-Ganz 数据解读,Preload,Definition:Volume of blood in the ventricle at the end of diastole.,Swan-Ganz 数据解读,2010-3-28,Swan-Ganz Catheter CuiNa,Contractility,Definition:The inotropic state of the myocardium The velocity a
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 最新 SwanGanz 导管 应用 技巧 临床 解读 课件 幻灯 pptPPT 文档