CETP00.00L467全球实验室加速循环腐蚀试验.doc
《CETP00.00L467全球实验室加速循环腐蚀试验.doc》由会员分享,可在线阅读,更多相关《CETP00.00L467全球实验室加速循环腐蚀试验.doc(19页珍藏版)》请在三一办公上搜索。
1、1.0INTRODUCTION 介绍1.1TEST SCOPE 试验范围This standard specifies an accelerated laboratory atmospheric corrosion test. The testing environment addressed is similar in effect to that of the salt load/ climatic part of the proving ground corrosion test procedure, CETP 00.00-R-343 and yields corresponding r
2、esults. The objective of the test is to allow evaluation of the corrosion resistance of metals in environments where there is a significant influence of chloride ions, mainly as sodium chloride from a marine source or by winter road de-icing salt. The laboratory test provides full exposure to the sa
3、lt load and humidity environment. It does not attempt to simulate other engraving factors such as mud loads, temperature stresses or wear. It serves as a general purpose atmospheric corrosion test and applies to a variety of materials, coatings, and interactions of materials, both as test specimens
4、or in designed components. The test can be used as a design verification method in order to (a) develop and qualify new corrosion resistant products, (b) develop new pre-treatments and finishing processes, (c) select materials and, (d) perform quality control of the final product. 本标准是关于一项在实验室里加速进行的
5、大气腐蚀试验。本文所述的试验环境类似于试验场腐蚀试验程序CETP00.00-R-343中的盐负荷/环境影响部分,得出相应的结果。试验目的在于评估金属在富含氯化物的环境中(主要是海水中的盐或冬天用于融雪的盐)的抗腐蚀性。该实验室试验主要是将试验件完全暴露在湿润的盐负荷环境中,而非模拟其他摩擦因素如泥负荷、温度压力或磨损。该试验主要作为一项大气腐蚀试验,适用于各种各样的材料、涂层、试样或设计零部件材料的相互作用。该试验可作为一种验证设计的方法,用于(a)开发并验证新的抗腐蚀产品;(b)开发新的预处理和表面处理工艺;(c)选择材料;(d)对最终产品的质量控制。The standard specifi
6、es controlled conditions for equipment and procedures to allow the test to be performed with a high degree of repeatability and reproducibility. It is designed to be suitable to run in various climate chambers, either as a fully automated procedure or with partial manual operations. 本标准说明了设备和程序的受控条件
7、,让实验具有高度的重复性和再现性。本标准适用于多种环境试验箱,包括全自动试验或部分手动操作的试验。1.2SUMMARY OF TEST CONTENT 试验内容摘要The workday test procedure consists of: 工作日的试验程序由以下几个方面组成: A 6 h wet phase at room temperature. with intermittent exposure to salt solution (0.5% NaCl). A 2.5 h transition phase with drying under climate control. A 15.
8、5 h phase with constant temperature and humidity (50C, 70% RH). 室温下6小时的加湿阶段,间歇曝露到0.5%的氯化钠溶液中 2.5小时的过渡阶段,通过环境控制进行烘干 15.5小时的恒温恒湿阶段(50C, 70% RH)After repeating this procedure Mon-Fri a 48 h weekend phase under continued constant climate control is added.从周一到周五重复该试验程序后,在周末加入持续恒定环境控,进行48小时的试验。1.3COMMONAL
9、ITY 共通性This is a CONTROL TEST and can be used to qualify components throughout the world. The test may be conducted at any location having the necessary equipment and facilities. Proposed revisions to this procedure must be submitted per FAP03-179. 这是一项可验证世界上所有的零部件的控制试验,可在任何地方进行,只要具备所需的设备仪器。对本试验程序的修
10、改建议必须按FAP03-179提交。2.0INSTRUMENTATION 仪器The following elements are usually required to conduct the test procedure:进行试验程序一般需要以下仪器:2.1Compressed, clean air of 4 - 6 bars for cleaning salt solution from spray nozzles, as a source for the renewal of chamber air and for humidification, supplied by spray h
11、umidifiers.2.1 4-6 bar的干净的压缩空气,用于清理喷嘴上的盐溶液、箱内换气和喷雾加湿器进行加湿。2.2A low conductivity water supply (20 mS max) for humidification or evaporative spray humidifiers and for the preparation of salt solutions. 2.2 一根低导电率的供水管(最大20 mS),用于加湿或喷雾加湿器以及准备盐溶液。2.3A tank for preparation and storage of salt solution or,
12、 alternatively, a system for direct on-line mixing of water and saturated NaCl solution to the actual concentration (0.5 0.05% by weight)2.3 一个用于准备和存储盐溶液的水槽,或者一套直接在线按实际浓度(0.5 0.05%,按重量)混合水和饱和氯化钠溶液的系统。2.4A conductivity meter with built-in temperature compensation for preparation and control of the 0.
13、5% NaCl salt solution (conductivity: 8.3 mS/cm + 0.80 at 20C). A 0.50% by weight NaCl solution is used as a calibration standard at each measurement.2.4 一个带内置温度补偿的电导仪,用于准备和控制0.5%的氯化钠盐溶液(温度为20C时的导电性:8.3 mS/cm + 0.80)。 一份按重量为0.50%的氯化钠溶液,作为每次测量时的校正标准。2.5A high quality device for independent control of
14、temperature and relative humidity shall be accessible. This instrument shall on a stipulated regular interval (Ref 5.4) be used for independent monitoring and calibration of the conditions in the very test plane of the exposure chamber. The total measurement error must not exceed 0.1C.2.5 一套高质量的设备,用
15、于独立控制温度和相对湿度。该设备按照规定的时间间隔(参考5.4),独立监控和校正试验箱李的试验平面上的各项条件,测量总误差不超过0.1C。2.6Racks of inert material for support and aligned fixation of test specimens must not hamper a free air-flow around the test objects, nor collect standing wetness. The test objects in a rack must not screen one another from the sa
16、lt solution downfall and they should be exposed with the stipulated exposure angle to the spray (15- 20 degrees inclination from vertical).2.6 由惰性材料制成的夹具,用于支撑、排列和固定试样,但不得妨碍试样周围的空气流通,不得累积水分。夹具上的试样不得相互遮蔽导致盐溶液淋不到试样上。试样应按规定的角度曝露到喷雾中(偏离垂直线15-20度)。2.7Pressurized hand-spray equipment for application of the
17、 0.5% NaCl solution if a manual spray procedure is used. The capacity must be sufficient to meet the downfall requirement (Ref. 3.3.1).2.7 如需采取手动喷洒,应使用适用于0.5%盐溶液的加压型手动喷雾器,喷雾器的容量必须能满足喷洒要求(见3.3.1)。2.8Funnels, beakers/ measuring glasses and a balance with at least 0.1 g accuracy for monitoring and cali
18、bration of salt solution downfall throughout the test plane of the exposure chamber.2.8 漏斗、烧杯/量杯以及精确度至少为0.1g的天平,用于监控和校准曝露箱中试验平面上落下的盐溶液。2.9All test measurement equipment must be calibrated and maintained per FAP03-015, Control, Calibration, and Maintenance of Measurement and Test Equipment.2.9 所有试验的测
19、量设备的校准和维护必须按照FAP03-015测量和试验设备的控制,校准和维护程序。2.10All applicable safety guidelines and procedures must be followed.2.10 试验须遵守所有适用的安全指引和安全程序。3.0EQUIPMENT AND FACILITIES 设备设施The necessary, permanently installed facility to conduct the test consists of a programmable humidity chamber of good quality. It is
20、preferably equipped with an integrated rig for spraying salt solution of the required amount and accuracy, cooling capacity and a good internal circulation system for the conditioned air (Fig. 1). The exposure chamber shall be designed so that the test conditions described in the subsequent paragrap
21、hs can be obtained, controlled, and monitored during the test.试验所需的永久性安装的设施包括一个可编程的高质量湿度箱。湿度箱中最好能配备一套喷量准确度高的综合性盐雾喷洒装置、冷却装置和一套性能良好的空气内循环系统(如图1)。曝露箱应按要求设计,以使下文所述的试验过程中的各项条件能在得到满足、控制和监控。Fig. 1 Schematic view of a climate chamber equipped with functions suited for performance of the described test proce
22、dure: 1. Chamber test space, 2. Climatization unit, including fan, heating, cooling and humidification, 3. Test plane with samples, 4. Temperature/ humidity sensor for regulation, 5. Insulated walls/ lids, 6. Diffusors for improved air distribution, 7. Fresh air inlet/ bleed, 8. Rain rig with nozzle
23、s and motor for swaying mode, 9. Gutter, 10. Control/ steering/ recording unit, 11. Position for monitoring/ calibration of climate with independent temperature/ humidity sensor.图1 环境试验箱的图示,配备了进行本文所述的试验程序所需的功能:1. 试验空间;2. 环境系统,包括风扇、加热器、冷却器和加湿器;3. 放置试样的平面;4. 温湿传感器(调节用);5. 隔热壁/盖; 6. 空气扩散器(改善空气分布);7. 新鲜
24、空气进气口; 8. 带喷头和摇摆模式驱动马达的喷洒器;9. 排水口;10. 控制/操作/记录系统;11. 带独立温室感应器的环境监控/校正位置。3.1CLIMATE CONTROL 环境控制The humidity and temperature levels of the chamber during the test cycle shall be continuously monitored. The sensors should reflect the climate conditions in the test plane (Fig. 1, item 4). The mean valu
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CETP00 00 L467 全球 实验室 加速 循环 腐蚀 试验
链接地址:https://www.31ppt.com/p-4219503.html