音频信号发生器毕业设计外文翻译.doc
《音频信号发生器毕业设计外文翻译.doc》由会员分享,可在线阅读,更多相关《音频信号发生器毕业设计外文翻译.doc(31页珍藏版)》请在三一办公上搜索。
1、本科毕业设计(论文)外文翻译原文学生姓名: 何 晓 君 院 (系):电 子 工 程 学 院 专业班级: 测控0602班 指导教师: 薛 晓 书 完成日期:2010年4月20日 Expanding the Features of a VIYou can choose one of many LabVIEW VI templates to use as a starting point. However, sometimes you need to build a VI for which a template is not available. This chapter teaches you
2、how to build and customize a VI without using a template.Building a VI from a Blank TemplateIn the following exercises, you will open a blank VI and add Express VIs and structures to theblock diagram to build a new VI. You will build a VI that generates a signal, reduces the number of samples in the
3、 signal, and displays the resulting data in a table on the front panel. When you complete the exercises, the front panel of the VI will look similar to the front panel in Figure 3-1.You can complete the exercises in approximately 30 minutes. Figure 3-1. Front Panel for the Reduce Samples VI Opening
4、a Blank VIIf no template is available for the task you want to create, you can start with a blank VI and add Express VIs to accomplish the specific task. Complete the following steps to open a blank VI. 1. In the LabVIEW dialog box, click the arrow on the New button and select BlankVI from the short
5、cut menu or press the keys to open a blank VI. Notice that a blank front panel and block diagram appear. Note You also can open a blank VI by selecting Blank VI from the Create new list in The New dialog box or by selecting FileNew VI from the front panel or block diagram menu bar.2. If the Function
6、s palette is not visible, right-click any blank space on the block diagram to bring up the temporary version of the Functions palette. Click the thumbtack, shown at left, in the upper left corner of the Functions palette to place the palette on the screen.Note You can right-click on a blank space on
7、 the block diagram or the front panel to bring up the Functions or Controls palettes.Adding an Express VI that Simulates a SignalComplete the following steps to find the Express VI you want to use and then add it to the block diagram.1. If the Context Help window is not visible, press the keys to op
8、en the Context Help window. You also can press the Show Context Help Window button, shown at left, to open the Context Help window.2. Select the Input palette on the Functions palette and move the cursor over the Express VIs on the Input palette.Notice that the Context Help window displays informati
9、on about the function of each Express VI.3. From the information provided in the Context Help window, find theExpress VI that can output a sine wave signal.4. Select the Express VI and place it on the block diagram. The Configure Simulate Signal dialog box appears.5. Idle the cursor over the various
10、 options in the Configure Simulate Signal dialog box, such as Frequency (Hz), Amplitude, and Samples per second (Hz). Read the information that appears in the Context Help window.6. Configure the Simulate Signal Express VI to generate a sine wave with a frequency of 10.7 and amplitude of 2.7. Notice
11、 how the signal displayed in the Result Preview window changes to reflect the configured sine wave.8. Close the Configure Simulate Signal dialog box.9. Move the cursor over the Simulate Signal Express VI and read the information that appears in the Context Help window.Notice that the Context Help wi
12、ndow now displays the configuration of the Simulate Signal Express VI.10. Save this VI as Reduce Samples.vi to an easily accessible location.Modifying the SignalComplete the following steps to use the LabVIEW Help to search for the Express VI that reduces the number of samples in a signal.1. Select
13、HelpVI, Function, & How-To Help to open the LabVIEW Help.2. Click the Search tab and type sample compression in the Type in the word(s) to search for text box.Notice that this word choice reflects what you want this Express VI to docompress, or reduce, the number of samples in a signal.3. Select the
14、 Sample Compression Express VI topic to display the topic that describes the Sample Compression Express VI.4. After you read the description of the Express VI, click the Place on the block diagram button, shown at left, to select the Express VI.5. Move the cursor to the block diagram.Notice how LabV
15、IEW attaches the Sample Compression Express VI to the cursor.6. Place the Sample Compression Express VI on the block diagram to the right of the Simulate Signal Express VI.7. Configure the Sample Compression Express VI to reduce the signal by a factor of 25 using the mean of these values.8. Close th
16、e Configure Sample Compression dialog box.9. Using the Wiring tool, wire the Sine output in the Simulate Signal Express VI to the Signals input in the Sample Compression Express VI.Customizing the Front PanelIn the previous exercises, you added controls and indicators to the front panel using the Co
17、ntrols palette. You also can add controls and indicators from the block diagram. Complete the following steps to create controls and indicators. 1. Right-click the Mean output in the Sample Compression Express VI and select CreateNumeric Indicator to create a numeric indicator.2. Right-click the Mea
18、n output of the Sample Compression Express VI and select Insert Input/Output from the shortcut menu to insert the Enable input.3. Right-click the Enable input and select CreateControl to create the Enable switch.4. Right-click the wire linking the Sine output in the Simulate Signal Express VI to the
19、 Signals input in the Signal Compression Express VI and select CreateGraph Indicator.Notice that you can create controls and indicators from the block diagram. When you reate controls and indicators using this method, LabVIEW automatically creates terminals that are labeled and formatted correctly.5
20、. Using the Wiring tool, wire the Mean output in the Sample Compression Express VI to the Sine terminal. Notice that the Merge Signals function appears.6. Arrange the objects on the block diagram so that they appear similar to Figure 3-2.Tip You can right-click any wire and select Clean Up Wire from
21、 the shortcut menu to have LabVIEW automatically arrange the wires for you.Figure 3-2. Block Diagram for the Reduce Samples VI7. Display the front panel.Notice that the controls and indicators you added automatically appear on the front panel with labels that correspond to their function.8. Save thi
22、s VI.Configuring the VI to Run Continuously Until the User Stops ItIn the current state, the VI runs once, generates one signal, then stops executing. To run the VI until a condition is met, you can add a While Loop to the block diagram. Complete the following steps to add a While Loop.1. Display th
23、e front panel and run the VI.Notice how the VI runs once and then stops. Also notice how there is no STOP button.2. Display the block diagram and select the While Loop on the Execution Control palette.3. Move the cursor to the upper left corner of the block diagram. Place the top left corner of the
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 音频 信号发生器 毕业设计 外文 翻译

链接地址:https://www.31ppt.com/p-4153005.html