中国联通WCDMA配套CESR7750设备巡检——ASB.doc
《中国联通WCDMA配套CESR7750设备巡检——ASB.doc》由会员分享,可在线阅读,更多相关《中国联通WCDMA配套CESR7750设备巡检——ASB.doc(8页珍藏版)》请在三一办公上搜索。
1、中国联通WCDMA配套CE SR7750设备巡检 上海贝尔股份有限公司QACC CSC TMS二00九年四月SR7750设备检查常规部分1. show card检查系统是否检测到所有已安装的IOM模块, 结果记录:A:xx-xx-CE-2 # show card =Card Summary=Slot Provisioned Equipped Admin Operational Card-type Card-type State State -1 iom2-20g iom2-20g up up 3 iom2-20g iom2-20g up up 8 iom2-20g iom2-20g up up
2、 10 iom2-20g iom2-20g up up A sfm-400g sfm2-200g up up/active B sfm-400g sfm2-200g up up/standby = 若出现card异常,先收集TS文件,后马上拔插card;若拔插无效,则需要做更换备件。2. show mda 检查是否所有mda板卡都是up状态结果记录:A: xx-xx-CE-2 # show mda =MDA Summary=Slot Mda Provisioned Equipped Admin Operational Mda-type Mda-type State State -1 1 m10
3、-1gb-sfp-b m10-1gb-sfp-b up up 2 m10-1gb-sfp-b m10-1gb-sfp-b up up 3 1 m10-1gb-sfp-b m10-1gb-sfp-b up up 2 m10-1gb-sfp-b m10-1gb-sfp-b up up 8 1 m10-1gb-sfp-b m10-1gb-sfp-b up up 2 m10-1gb-sfp-b m10-1gb-sfp-b up up 10 1 m10-1gb-sfp-b m10-1gb-sfp-b up up 2 m60-10/100eth-tx m60-10/100eth-tx up up =若出现
4、mda异常,先收集TS文件,后马上拔插mda;若拔插无效,则需要做更换备件。3. show chassis power-supply电源运行状况结果记录:A: xx-xx-CE-2 # show chassis power-supply =Chassis Information=Power Supply Information Number of power supplies : 2 Power supply number : 1 Defaulted power supply type : dc Status : up Power supply number : 2 Defaulted pow
5、er supply type : dc Status : up =电源采用11备份方式工作,1路电源故障的情况下并不会影响到业务,但需要尽快申请电源备件。7. show system cpu检查CPU运行负荷(Idle状态不应低于60)结果记录:A: xx-xx-CE-2 # show system cpu =CPU Utilization (Test time 999551 uSec)=Name CPU Time CPU Usage (uSec) -System 31865 3.18% Icc 782 0.07% RTM/Policies 0 0.00% OSPF 13 0.00% MPLS
6、/RSVP 123 0.01% LDP 145 0.01% IS-IS 944 0.09% RIP 32 0.00% VRRP 579 0.05% BGP 603 0.06% Services 409 0.04% IOM 0 0.00% CFLOWD 0 0.00% IGMP 0 0.00% PIM 0 0.00% MCast Stack 0 0.00% IP Stack 5914 0.59% MBUF 0 0.00% IGMP Snooping 182 0.01% TLS MFIB 667 0.06% WEB Redirect 144 0.01% MSDP 0 0.00% Idle 9571
7、49 95.75% =若出现低于60的情况,应立即关注高占有率的进程,并分析原因。8show system memory-pools内存使用,可用内存应大其他项一个数量级。结果记录:A:AH-HF-WLD-CE-1 # show system memory-pools =Memory Pools=Name Max Allowed Current Size Max So Far In Use -System No limit 99,341,328 112,178,304 85,549,136 Icc 8,388,608 1,048,576 1,048,576 715,280 RTM/Polici
8、es No limit 10,485,760 10,485,760 6,643,664 OSPF No limit 3,145,728 3,145,728 2,795,552 MPLS/RSVP No limit 6,745,768 6,745,768 6,570,376 LDP No limit 2,097,152 2,097,152 1,313,792 IS-IS No limit 4,505,664 4,505,664 3,672,912 RIP No limit 0 0 0 VRRP No limit 1,048,576 1,048,576 101,024 BGP No limit 1
9、8,350,272 18,350,272 17,825,216 Services No limit 9,047,520 9,047,520 7,778,808 IOM No limit 0 0 0 CFLOWD No limit 0 0 0 IGMP/MLD No limit 0 0 0 PIM No limit 0 0 0 MCast Stack No limit 0 0 0 IP Stack No limit 20,599,736 20,599,736 19,392,280 DHCP server No limit 1,048,576 1,048,576 190,112 MBUF No l
10、imit 5,837,312 5,837,312 4,900,208 IGMP/MLD Snpg No limit 2,306,112 2,306,112 1,411,112 TLS MFIB No limit 1,048,576 1,048,576 980,536 WEB Redirect 8,388,608 2,097,152 2,097,152 1,378,032 MSDP No limit 0 0 0 BFD No limit 1,048,576 1,048,576 307,576 MCPATH No limit 1,048,576 1,048,576 200 -Current Tot
11、al Size : 190,850,960 bytesTotal In Use : 161,525,816 bytesAvailable Memory : 1,767,279,216 bytes=9. show log log-id 99 sev major日志中的严重告警结果记录:A:NX-YC-ESN-CE-1 # show log log-id 99 =Event Log 99=Description : Default System LogMemory Log contents size=500 next event=269394 (wrapped)269391 2008/12/02
12、16:25:35.77 GMT8 MAJOR: SVCMGR #2210 Base Processing of an access port state change event is finished and the status of all affected SAPs on port 5/2/58 has been updated.269386 2008/12/02 16:18:27.66 GMT8 MAJOR: SYSTEM #2002 Base Configuration Save SucceedsConfiguration file saved to: cf3:config.cfg