1、本科毕业设计外文文献及译文文献、资料题目:The fire safety design of apartment buildings文献、资料来源:著作文献、资料出版日期:2001院 (部): 市政与环境工程学院专 业: 给水排水工程班 级: 姓 名: 学 号: 指导教师: 翻译日期: 2008.6外文文献:THE FIRE SAFETY DESIGN OF APARTMENT BUILDINGS13 FIRE SAFETY MATRIXThe objective of this fire safety matrix is to provide a guide for the fire eng
2、ineering design of apartment buildings. The matrix is only intended for guidance and an appropriately qualified fire safety engineer should verify the final design. The three main fire scenarios that should be considered in the design of apartment buildings are: a smouldering fire in an apartment, a
3、 flaming fire in an apartment and a fire in common spaces (ie stairs and corridors). Irrespective of the building and occupant characteristics, some minimal fire safety measures should be implemented in all apartments. The following is a list of essential fire safety measures that should be provided
4、 in all apartment buildings:1 Smoke detectors2 Heating, ventilation and air conditioning (HVAC) system to shut down on fire alarm3 A 30-minute minimum fire resistance between apartments, vertical shafts and floors.13.1 Emergency strategyBrief descriptions of the emergency strategy, or emergency plan
5、s used in the matrix are provided below.1 Evacuation on alarm all occupants evacuate the building.2 Non evacuation occupants in the room of fire origin evacuate the building. Other occupants remain in their rooms, waiting for fire brigade assistance and advice, and carry out protect-in-place activit
6、ies.3 Staged evacuation occupants in the room of fire origin and on the fire floor evacuate first. The remaining occupants are directed to evacuate automatically in the following sequence until the fire brigade intervenes. Occupants immediately above the fire floor evacuate after those on the fire f
7、loor, followed by the floors above. Occupants on levels below the fire floor are evacuated last.Fire brigade intervention can alter the sequence of evacuation, or halt the evacuation in response to current conditions or any changes.13.2 Occupants at riskFor the three fire scenarios and the three eme
8、rgency strategies, the following matrix outlines the occupants that are most at risk.13.3 Matrix variablesThe fire safety design of apartment buildings consists of numerous variables and interdependencies. These variables have to be considered concurrently to provide the most effective design.The se
9、lection of fire safety measures in many cases results in a trade-off between various alternatives. For example, sprinkler protection can permit a reduction in fire resistance rating required for buildings and may allow extended travel distances. These trade-offs and interrelationships between fire s
10、afety measures need to be considered to obtain the most efficient and effective fire safety design.Table 14 lists some of the fire safety measures that should be considered for apartment buildings. The variables presented are not a comprehensive list, and other fire safety measures may be more appro
11、priate for more complex designs.Table 14 Matrix variables13.4 Buildings greater than 25mThe fire safety matrix for buildings greater than 25m high is presented in Table 15. The matrix provides the recommended fire safety measures for apartment buildings with respect to sprinkler protection and the e
12、mergency strategy. The matrix provides a simple method of determining some of the minimum fire safety requirements of an apartment building. It can also be used to evaluate which type of emergency strategy would be most effective, or when sprinklers would be beneficial given certain building conditi
13、ons. The justification of the recommended fire safety measures is pvided in Section 14.1.Table 15 Fire safety matrix: buildings greater than 25mthe above matrix are designed to provide at least two levels of protection for the occupants. As the building height increases, the number of fire protectio
14、n measures also increases to provide additional levels of protection and maintain the level of safety for the occupants.Table 16 summarises the occupants who are most at risk and the levels of fire safety provided by the above fire safety matrix. Table 17 provides the cell key for identifying the de
15、signated cells in Table 16. This key remains the same for all cases presented.Table 16 Levels of fire safety (buildings greater than 25m)Table 17 Cell key13.5 Buildings greater than three storeys and less than 25mThe fire safety matrix for buildings greater than three stories and less than 25m high
16、is presented in Table 18. The justification of the recommended fire safety measures is provided in Section 14.2.Table 18 Fire safety matrix: buildings greater than three storeys and less than 25mTable 19 Levels of fire safety (buildings greater than three storeys and less than 25m)13.6 Buildings les
17、s than three storeysThe fire safety matrix for buildings less than three stories is presented in Table 20. The justification of the recommended fire safety measures is provided in Section 14.3.Table 20 Fire safety matrix: buildings less than three storeysTable 21 Levels of fire safety (buildings les
18、s than three storeys)14 DISCUSSION OF FIRE SAFETY MATRIXThe fire safety matrix considers the building height, sprinkler protection and the emergency strategy as the primary variables. This is due to the high influence that the interactions of these variables have on other fire safety measures. In ad
19、dition to this, the fire engineer can specify the emergency strategy and sprinkler protection for the building that will provide flexibility to the matrix. Therefore once the extent of these three variables has been determined the remaining fire safety systems can be selected to suit the building.Th
20、e objective of the fire safety recommendations is to address key issues that result from a given set of building characteristics, while providing multiple levels of protection for occupants in the event of a fire. This provides a backup or redundancy in the design in the event of one part of the sys
21、tem failing. For example, if the sprinkler system fails the occupants will be protected with passive protection and smoke control systems.The following sections discuss the three building height limits with respect to the fire safety measures that have been recommended. The staged evacuation strateg
22、y has not been discussed separately as it is a combination of the other two strategies and the same fundamental principles apply.14.1 Buildings greater than 25m in height.Once buildings exceed 25m in height, the ability of the fire brigade to rescue occupants externally becomes limited. Therefore, a
23、 higher level of fire safety needs to be provided to the stairs and escape paths. Emergency lifts are also considered an option to provide rapid access for the fire brigade and egress for disabled occupants.As buildings become taller the level of fire protection needs to increase. This is due to:1 F
24、urther travel distances, resulting in a higher chance of exposure to fire and fireproducts, and longer exposure time.2 The reduced ability of the fire brigade to rescue people externally3 The increased time for the fire brigade to reach upper levels4 More occupants, resulting in a higher risk of inj