火灾报警系统英文文献.doc
《火灾报警系统英文文献.doc》由会员分享,可在线阅读,更多相关《火灾报警系统英文文献.doc(10页珍藏版)》请在三一办公上搜索。
1、 本科毕业设计(论文) 中英文对照翻译院(系部) 机械与动力工程学院 专业名称 测控技术与仪器 年级班级 08级3班 学生姓名 牛 彦 杰 指导老师 赵 彦 如 2012年6月8日The Fire Auto-alarm System DesignFire control work shall follow the policy of devoting major efforts into prevention and combining fire prevention with fire fighting, and shall adhere to the principle of combin
2、ing the efforts of both specialized organizations and the masses and carry out responsibility system on fire prevention and safety. The State Council shall led and the peoples governments at all levels be responsible for fire control work. The peoples government at all levels shall bring fire contro
3、l work in line with the national economy and social development plan, and ensure that fire control work fit in with the economic construction and social development. The public security department of the State Council shall.Monitor and administer the nationwide fire control work; the public security
4、 organs of local peoples governments above county level shall monitor and administer the fire control work within their administrative region and the fire control institutions of public security organs of the peoples government at the same level shall be responsible for the implementation. Along wit
5、h the our country economic development rapid development, the lives of the people level unceasing enhancement, the city uses to be day by day anxious, urges the building to face the direction is developing. This kind of high level civil construction repair needed materials and the way also more hast
6、en the diversification, and along with uses electricity the load and coal gas consumption quantity enlarging.Proposed to the fire auto-alarm system design is higher, a stricter request. In order to guarantee the people life and property the security, the fire auto-alarm system design has become in t
7、he high level civil construction design one of most important design contents. The establishment of the monitoring role of the author about the fire alarm systems in the design of tall buildings on the basis of experience, it is proposed that details of the relevant national standards and standards
8、is not clear simple views through group discussion and point out the error.First, design basisThe fire auto-alarm system design is a specialized very strong technology work, at the same time also has the very strong policy-type. Therefore, first should be clear about the following design basis:1st,
9、must grasp the architectural design fire protection standard, the system design standard, the equipment manufacture standard, the installment construction approval standard and the administration laws and regulations and so on five big aspects fire laws and regulations, and in practical understandin
10、g present country related standard and standard positive word: Must, be supposed, to be suitable, may and the reverse side word: Strictly prohibits, should not, not have, not to be suitable the meaning.2nd, must aim at high level civil building function, use and the protection object fire protection
11、 rank, earnestly carries out the present national related standard, earnestly treats the public security fire prevention surveillance department the examination and approval opinion.Second, fire auto-alarm system equipment establishmentFire detector establishmentOpens wide either the seal or the sta
12、ir hall should alone divide the search coverage.Room (including guards against in front of smoke stair hall in front of room, fire elevator room, fire elevator with guards against the front room which smoke stair hall comes in handy) and the aisle should distinguish alone to divide the search covera
13、ge, specially front the room and the lift well, the scattered stair hall and the aisle are interlinked, has time the fire haze to be easier to gather or to flow, is the personnel disperses which saves goal with the fire prevention, therefore should install the fire detector. Regarding common elevato
14、r in front of room is not the personnel disperses , but this front room and the lift well are interlinked, has time the fire haze to be also easy to gather or to flow, suitably alone divides the search coverage and installs the fire detector.The electric cable shaft therefore is easy to form pulls o
15、ut the smoke inflammation the channel; Has when the fire the fire intensity not easily extends along the electric cable burns, for this, the high level civil construction design fire protection standard and the civil construction electricity design standard separately proposes the detailed specific
16、stipulation in the construction and in the electric wire or on the electric cable shaping. But considered implements specifically the difficulty and the present situation, the electric cable shaft installs the fire detector is extremely essential, and coordinates the shaft the fire protection separa
17、tion request, each 2 3 or each level installs.The elevator machine room should install the fire detector, its elevator is the important vertical transportation vehicle. When has the fire, the lift well often becomes the fire intensity spread the channel, is easy to threaten the elevator machine room
18、 the facility. Therefore, the elevator machine room establishes the fire detector is necessary, crown of also suitable establishment fire detector lift well.2nd, the manual fire reports to the police the button establishmentRoom (Including guards against in front of smoke stair hall in view of vario
19、us floors front room in front of room, fire elevator room, fire elevator with guards against which smoke stair hall to come in handy the front room) is has when the fire the personnel to disperse which saves goal with fire prevention, should report to the police the button first choice spot as the e
20、stablishment manual fire. In addition, the room also should establish the manual fire to the common elevator in front of to report to the police the button.In the public active place (including hall, dining room, multi-purpose hall and so on) and the main thoroughfare and so on place, the personnel
21、very is all centralized, and mainly disperses the channel. Therefore should report to the police the button in these public active places main access establishment manual fires; The manual fire establishes which in the main thoroughfare reports to the police the button to guarantee to a manual fire
22、which most is close to reports to the police the button distance from a fire protection district any position not to be supposed to be bigger than 30 meters.3rd, the fire emergency broadcasts the speaker the establishmentThe aisle, the hall, the dining room and so on the public place personnel very
23、are all centralized, and mainly disperses the channel. Therefore should press in these public places to a recent speaker distance is not bigger than 25 meters from a fire protection district any spot and in the aisle last should not be bigger than 12.5 meters the speaker to the aisle terminal distan
24、ce the establishment fire emergency to broadcast the speaker; Next also should establish the fire in the public bathroom place emergency to broadcast the speaker.Room (combined before the smoke staircase room, firemans lifts the front room, fire lift) and smoke staircase and walkways should be a sep
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 火灾 报警 系统 英文 文献
链接地址:https://www.31ppt.com/p-2858937.html