BPRQ318 Packaged Water Processing包装水工艺过程0924.doc
《BPRQ318 Packaged Water Processing包装水工艺过程0924.doc》由会员分享,可在线阅读,更多相关《BPRQ318 Packaged Water Processing包装水工艺过程0924.doc(8页珍藏版)》请在三一办公上搜索。
1、包装水工艺过程 Purpose目的Manufacture products of The Coca-Cola Company using robust processes and controls in order to meet regulatory requirements and Company specifications使用加强的工艺过程和控制制造可口可乐公司产品,是为了符合调整的要求和公司规范。Scope范围Apply to operations manufacturing packaged processed water and packaged natural source w
2、ater. 适用于操作生产包装加工水和包装天然来源的水。Definitions定义Packaged Processed Water Packaged drinking water, except natural source waters. Includes treated water, water with minerals added or removed. 包装加工水包装饮用水,除了天然水源的水。包括处理水,加入或是取出矿物质的水。Packaged Natural Source Water Packaged water from a defined groundwater source
3、with restrictions on permitted treatments. Includes Natural Mineral Water (NMW) and Spring Water.包装天然来源的水包装水来自特定的地下水源,在处理方面有限制。包括天然矿物质水(NMW)和泉水。 Packaged Processed Water Requirements包装加工水的要求Follow the Processing and Filling General Requirements以下是工艺过程和灌注的一般要求Follow Company, Group/Business Unit or ap
4、plicable regulations, whichever is stricter. 要遵循总部、可口可乐地区总部或是可适用的规定,以更严格的为准。Approved treatment methods for packaged processed water are:对于包装加工水允许的处理方法是:Carbonation If CO2 is greater than or equal to 1.7 volumes, then follow Carbonated Processing. BP-RQ-308。If CO2 is less than or equal to 1.7 volumes
5、, then pasteurization or ozonation is required l 碳酸化如果二氧化碳大于等于1.7个体积,就遵循碳酸工艺过程。BP-RQ-308,如果二氧化碳小于等于1.7个体积,那么就需要巴氏消毒或臭氧消毒。 NOTE: When using CO2 as a processing aid for pH control, it must be pasteurized or ozonized . The pH of the final beverage must meet the pH indicated in the master formula; other
6、wise, reformulation of the product must be requested. 注意:当使用二氧化碳作为控制pH值的工艺助剂时,它必须经过巴氏消毒或臭氧消毒。终产品的pH值必须符合产品配方的要求;否则,必须提出修改配方的申请。l Pasteurization :巴氏消毒: l For hot-fill follow Hot-fill Processing , BP-RQ-316. 热灌装遵循热灌装工艺过程,BP-RQ-316.。l For aseptic fill, follow Aseptic Processing ,BP-RQ-304. 无菌灌装遵循无菌灌装工艺
7、过程,BP-RQ-304。l Ozonation Follow this document. 臭氧遵照此文件。l Implement a Bioburden Monitoring plan for filling room environment. 对注入间环境实施微生物监控计划。l Meet requirements in Water Use in Water for Product Manufacturing, BP-RQ-180 and Packaged Water Specifications and Monitoring, BP-SP-182 before microfiltrati
8、on and UV are applied 在微过滤和紫外线灯应用之前,要符合用于产品制造的用水要求(BP-RQ-180)和包装水规范和监控要求(BP-SP-182)。l The parameters for the treatment methods are contained in the Master Mixing Instructions or from documentation from the Group/Business Unit处理方法的参数包含在混比规程中,或集团/可乐的相关文件Ozonation 臭氧Use only containers and closures app
9、roved for ozonated water. 臭氧水只使用认可的容器和盖子。 Generate ozone gas on site.臭氧气体必须是在现场产生的. Install a feedback loop to control ozone damage and an in-line monitoring and alarm system to ensure uninterrupted ozone flow and concentration levels,需要安装一个反馈回路控制臭氧的剂量,连同一个在线监测和警报系统,确保持续的臭氧流通和浓度水平。l Control ozone co
10、ncentration and contact time to achieve ozone residual of 0.1 to 0.4 ppm when measured within 60 seconds after filling. Local regulatory requirements may supersede this requirement. 控制臭氧浓度和接触时间,使在灌注后60秒内检测时,臭氧残余达到0.1-0.4ppm。如各地区有相关法规,按法规执行 Monitor bromate in the packaged water to ensure levels meet
11、specification as listed in Packaged Water Specifications and Monitoring, BP-SP-182 . 监控包装水中的溴酸盐水平,确保标准符合包装水规范和监控BP-SP-182清单中列出的规范。 Refer to Compressed Gas Management for workplace monitoring requirements. 工作场所监控要求参考压力气体管理。 Before applying closures to polycarbonate bottles: 在给聚碳酸酯瓶封盖以前:o Overfill the
12、 bottles to ensure that the sealing surface is in contact with the ozonated product; and o瓶子装的溢出来,确保防盗环的表面接触到被臭氧化的产品;并且o Sterilize the closures by directing an ozonated water spray to the inside of each closure. o通过直接喷洒臭氧水的方法,给每个盖子的里面进行消毒。O Turn bulk containers (carboy, 5-gallon, etc.) and place hor
13、izontally after filling to ensure closure sterilization.O 灌装后倒置容器(大玻璃瓶,5加仑,等等)并将其水平放置,确保盖子被杀菌NOTE: Ozonation can generate bromate from bromide. Many treated waters have a level of bromide that could theoretically generate non- compliant bromate concentrations if not appropriately managed and monitor
14、ed. Refer to BP-SP-182 Packaged Water Specifications and Monitoring, and reference document RF-WA-267 Bromate Formation Monitoring and Control. 备注:臭氧能从溴化物中产生溴酸盐。很多处理水有溴化物的水平,这个水平如没有适当的管理和监控的话,理论上会产生不合适的溴酸盐的浓度。参考BP-SP-182包装水规范和监控,和参考文件RF-WA-267溴酸盐的监控和控制。Packaged Natural Source Water Requirements包装天然水
15、源水的要求 Treatments for natural source waters must comply with applicable regulations and have Group/Business Unit approval.天然水源水的处理必须符合当地规范和可口可乐地区总部的认可。Operations must: 操作必须l Follow Codex Standard 108-1981 at a minimum; and l 至少要遵循食品法典委员会标准108-1981;和l Applicable regulations; andl 适用的法规;和l Business Uni