慢性完全性闭塞的导丝技术介绍课件.ppt
《慢性完全性闭塞的导丝技术介绍课件.ppt》由会员分享,可在线阅读,更多相关《慢性完全性闭塞的导丝技术介绍课件.ppt(72页珍藏版)》请在三一办公上搜索。
1、Introduction wire techniques of chronic total occlusions,Jun Dai , M.D. Coronary disease center Fuwai Hospital CAMS & PUMC Beijing,Introduction wire techniques,Contents,DefinitionPathologyAngiography imagingPCI technical challenge guidewire technology interventional devices revascularization technol
2、ogy,ContentsDefinition,Definition of CTO,Chronic total occlusions are defined as occlusions greater than 3(1) month old with angiographic TIMI 0 or TIMI 1 flow,Definition of CTOChronic total,The Spectrum of Lumen Morphology in CTO: Clinical Challenges,Necrotic core,Proteoglycan-rich,Calcification,La
3、rge recanalizationchannels,Inflammation,Small recanalizationchannels,Fibrotic plq:Negativeremodelling,The Spectrum of Lumen Morpholo,Chronic Total Occlusions,Whats Blocking up the Lumen?1. Dense Fibrotic Tissue: COLLAGEN!2. Calcification,Chronic Total OcclusionsWhats,Intraluminal Collagen,Extracellu
4、lar Matrix: Collagen, Calcium,Increased fibrocalcific plaques with ageSrivatsa et al, J Am Coll Cardiol 1997:29:955-63,NCVIntraluminal CollagenExtrac,Intraluminal Calcification,Intraluminal Calcification,Variables related success,Age of OcclusionEntryLengthTortuousityCalciumCollateralsDistal Vessel
5、SizeIn-stent occlusiondevices,Variables related successAge o,Anatomic Descriptorsof Procedural Success,Anatomic Descriptorsof Proced,慢性完全性闭塞的导丝技术介绍课件,慢性完全性闭塞的导丝技术介绍课件,Anatomy of a CTO Guidewire,Guidewire Operator Techniques,Simplified “Lesion-Specific” CTO Guidewire Use Algorithms,CTO Guidewire Desi
6、gn,CTO Guidewire Categories,Anatomy of a CTO GuidewireGuid,Anatomy of a CTO Guidewire,Guidewire Operator Techniques,Simplified “Lesion-Specific” CTO Guidewire Use Algorithms,CTO Guidewire Design,CTO Guidewire Categories,Anatomy of a CTO GuidewireGuid,Hallmarks of a CTO Guidewire,Tip styles - core-to
7、-tip designs; sometimes tapered Coils and covers - some favor increased radiopacity; jointless coils for improved torque response; polymer covers for selected applications Core tapers and materials - shorter tapers for improved torque response; generally stainless steel Core diameters - larger for i
8、ncreased support and torque response Coatings - hydrophilic for tracking (body) and hydrophobic for torque response (body and tip),Hallmarks of a CTO Guidewire T,ASAHI MIRACLEBROS Family Straight Tip Guide Wires,Characteristics:Core-to-tip design (unique wire drawing process)Non-tapered tip11 cm of
9、radiopacitySmooth tractability & delivery with Joint-less distal coil technologyHydrophobic coatingIncreasing tip loads 3 -12 gmExcellent tip shape ability & shape retention,ASAHI MIRACLEBROS 3ASAHI MIRA,慢性完全性闭塞的导丝技术介绍课件,ASAHI CONFIANZA 9 Tapered Tip Guide Wires,Characteristics:Very stiff tip 9 gm t
10、ip loadTapered tip - .009“ (for enhanced penetration)20 cm radiopacitiy - Joint-less technologyHydrophobic coating,ASAHI CONFIANZA 9ASAHI CONFIA,Hydrophilic Coating,0.014”,Radiopaque Spring Coil,0.008”,PTFE,ASAHI CONFIANZA Pro “8-20” Tapered Tip Guide Wire,Characteristics:Stiffest tip - 20 gmTapered
11、 tip - .00820 cm radiopacitiy Joint-less technologyHybrid coating,Greatest penetrating force,Hydrophilic Coating0.014”Radi,The combination of a polymer cover and hydrophilic coating provides outstanding lubricity.,Tip coils beneath the polymer help facilitate tip shaping.,HI-TORQUE PILOTTM Family of
12、 Guide wire,The combination of a polymer,Cordis SHINOBI & SHINOBI PlusCTO Guidewires,Unique flattened tip designed to cross subtotal occlusions,Flattened radiopaque coils,.0070” Corewire Support,SHINOBI,.0100” Corewire Support,SHINOBI Plus,Cordis SHINOBI & SHINOBI Plus,1. Coronary CTOs have many typ
13、esof lesion morphologies.,Therefore, we have to use different types of wiresfor different lesion morphologies.,2. During a single CTO-PCI procedure,we often encounter different kinds of situations.,Therefore, we have to use a different type of wirefor each situation.,Wire selection and wire handling
14、,1. Coronary CTOs have many typ,Guide Wire Selection,Most important considerationsTorque responseTip feel (tactile response)Tip shape curve formation,Guide Wire SelectionMost impor,Hydrophobic vs. Hydrophilic Wires,Hydrophobic wiresProvide better tactile response to operator Provide operator improve
15、d tactile response to better navigate micro-channelsTo get into the “dimple” and use tip load to purchase fibrous capHydrophilic wiresHydrophilic wires with tapered tip may improve the locating of micro-channels, however micro-channels can lead to false lumens/sub-intimal spacesHydrophilic wires ten
16、d to follow the path of least resistance and generally offer less tip control,Hydrophobic vs. Hydrophilic W,Simplifyed sequence of wires,Easy case ( big vessel, straight )Crossit 100Confianza pro,Difficult case (calcifyed, tortuous, smaller) Miracle 3gProx. Tortuosity: lubricious wiresMiracle 4.5-12
17、 gConfianza wires,Parallel wire: Confianza 6g 12g,Simplifyed sequence of wiresEa,Why so difficult to cross it ?,Why so difficult to cross it ?,Sub-Intimal Path,Sub-Intimal Path,Wire technique for locating another channel Tip Shape Is Key,Wire technique for locating a,Wire tip for CTO,CTO,Stenosis,Ti
18、p 1 mm,Tip 2-3mm,Wire tip for CTOCTOStenosisTip,Anatomy of a CTO Guidewire,Guidewire Operator Techniques,Simplified “Lesion-Specific” CTO Guidewire Use Algorithms,CTO Guidewire Design,CTO Guidewire Categories,Anatomy of a CTO GuidewireGuid,Guidewire Operator Techniques,Guidewire Operator TechniquesP
19、,DRILLING(controlled),Guidewire Operator Techniques,Short tip curve ( 2mm) at 45-60o; sometimes a proximal secondary curve at 15-30oControlled rotational tip motion with gentle forward probing Start with moderate stiffness tips and stepwise increases in tip stiffnessPremium on tactile responses,DRIL
20、LINGGuidewire Operator Tec,PENETRATION,Guidewire Operator Techniques,Similar tip shape and curves as drilling techniquePrecise movements of the guidewire tipMinimal rotational tip motion with more aggressive directed forward probingTip stiffness should penetrate even heavily calcified entry cap (9-1
21、2 gms and tapered)Reduced tactile responsiveness,PENETRATIONGuidewire Operator,Allways steer towards inner curve ! Twist gently , push and pull ! Dont inject dye via OTW-catheter !,Allways steer towards inner cu,In curved vessels, the optimal site for penetrating the fibrous cap is towards the myoca
22、rdium (mural ),No !,In curved vessels, the optimal,Penetration vs. Controlled Drilling Drilling,Techniques of CTO Guidewire Manipulation,Penetration vs. Controlled Dri,Techniques of CTO Guidewire Manipulation,Penetration vs. Controlled Drilling,Directional control of the tip is more precise in “Pene
23、tration”,Advancement of the tip is easier in “Controlled Drilling”,Techniques of CTO Guidewire Ma,SLIDING,Guidewire Operator Techniques,Longer and shallower tip shapes and no secondary bendsSimultaneous tip rotation and probingAlmost no tactile responseTakes advantage of reduced guidewire surface fr
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 慢性 完全性 闭塞 技术 介绍 课件
链接地址:https://www.31ppt.com/p-1972010.html