1、Capacitive IsolationA Technical Overview,Temperature,The RealWorld,Pressure,Position,Speed,Flow,Humidity,Sound,Light,TRANSCEIVERSRS-485/ CAN,Signal Isolation,What is Isolation?,Galvanic isolation: Although Circuit 1 and Circuit 2 exchange signals, no current (electrons) pass from Circuit 1 to Circui
2、t 2.Why is isolation required in electrical systems: Break ground loops Reduce common mode noise Safety from high voltages,Why Isolation?Ground Loops,More than one conductive path between two circuits creates a ground-loop Multiple ground paths may lead to unintended equalization currents,Ground loo
3、p can be broken by Disconnecting the grounds Common-mode chokes Frequency selective grounding Differential amplifiers Galvanic isolatorsOnly galvanic isolation provides protection for very large potential differences,Why Isolation?Common Mode Noise,Signals referencedto GND1,Basic/Functional Isolatio
4、nvs. Reinforced Isolation,“An improved basic insulation with such mechanical and electrical properties that, in itself, the insulation provides the same degree of protection against electrical shock as double insulation. It may consist of one or more layers of insulation material.” UL-60950-1,Basic/
5、Functional Isolationvs. Reinforced Isolation (contd),When is Reinforced required:6kVpp systems (e.g. 600V IGBTs/FETs)Today: all Medical applications (5kVrms!) Future: Medical applications for isolation from the patientNote: this is not complete and subject to change. Exceptions may apply!,Applicatio
6、ns utilizing Isolation,Primary Task:Isolation between High-Power and Control SignalsIsolation of Bus-Nodes to prevent Corruption of the complete Bus & Common Mode Rejection,Industrial: RoboticsPLC input/output isolationIndustrial networksMotor controlPower supplies,Applications utilizing Isolation,C
7、ommunications:PBX (Private Branch Exchange) and central officeTelephone terminal equipmentTelephone switching equipmentModemsISDNEthernet / PoE,Medical:Microwave therapyPatient monitoringElectrocardiographsDefibrillators,Primary Task:Medical:Isolation between Power and PatientCommunications:Isolatio
8、n between Power and CallerIsolation of Bus-Nodes to prevent Corruption of the complete Bus,Consumer Electronics:Video (TV, VCR, etc.)Plasma displaysElectronic gamingHome appliances,Applications utilizing Isolation,Computers & Office EquipmentIsolated I/OPrinters and plottersFax machines,Primary Task
9、:Isolation between High-Power and User,Nomenclatures / Definitions (1/3),Operation Voltage:Voltage that may be applied continuously across the Isolation barrier, mostly 560Vpk or 890VpkTransient Voltage:Voltage that may occur temporarily across the barrier (tested per VDE for 1 minute), mostly 4kVpk
10、 (relates to 3kVrms per UL, as tested for 10s only) or 6kVpkSurge VoltageSingle event surge, with the assumption that all effects have been recovered from prior to another surge-event, mostly rated for a 10kV single peak.,Nomenclatures / Definitions (2/3),Basic / Functional Isolation:Assumes a singl
11、e level of isolation with a certain strength. Applicable for most applications in industrial for fieldbusses and AC-equipment up to 400Vrms, and for consumer electronics. Mostly rated at 560Vpk continuous, 4kVpk transient voltage.Reinforced / Double Isolation:Double Isolation assumes a two-level iso
12、lation with a certain strength each. Reinforced addresses a single level of isolation that, however, provides the same reliability as the two-layer. Applicable for most medical applications and AC-equipment above 400Vrms. Mostly rated at 890Vpk continuous, 6kVpk transient , 10kV surge voltage. Medic
13、al needs 5kVrms transient.Intrinsically safe Applications demand double isolation.Note: the End-equipment-standard (e.g. IEC-60950 for communications or IEC-60601-1 for medical) dictates what is needed on silicon level,Nomenclatures / Definitions (3/3),Common Mode Transient Suppression:Discusses the
14、 quick change in Reference potential primary to secondary. Its given as the dU/dt up to which no false toggeling of the output will occur (e.g. 35kV/us). Usually scales linearly with Vcc.Creepage and ClearanceDiscusses the surface-distance that may conduct if wet/polluted, respectively the air-dista
15、nce. For 560V/4kV mostly 4mm is sufficient, for 890V/6kV mostly 8mm is needed. Depends on pollution degree,5 Questions, to allow educated solution-proposalsIsolation strength: basic/reinforced?Isolation voltage: 4kVpeak, 560Vpeak continuos / 6kVpeak, 890V peak continous?Stand-alone isolation or inte
16、gration (Transceiver, Gate-Driver, Data-Converter)?Supply Voltages?Channel-count?,New Generation Capacitive Isolation,High voltage capacitor,Isolator construction,Creepage distance: Shortest distance between two conductive input to output leads measured along surface of insulation.,Clearance distanc