【BS英国标准】BS EN 611692 Radiofrequency connectors. Sectional specification. Radio frequen.doc
BRITISH STANDARDBS EN61169-2:2007Radio-frequency connectors Part 2: Sectional specification Radio frequency coaxial connectors oftype 9,52The European Standard EN 61169-2:2007 has the status of aBritish StandardICS 31.220.10 BS EN 61169-2:2007National forewordThis British Standard was published by BSI. It is the UK implementation ofEN 61169-2:2007. It is identical with IEC 61169-2:2007. It supersedesBS EN 61169-2:2002 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling, to Subcommittee EPL/46/2, Radio frequency connectors and waveguides.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amd. No.DateCommentsThis British Standard was published under the authority of the Standards Policy and Strategy Committeeon 31 May 2007© BSI 2007ISBN 978 0 580 50821 9Amendments issued since publicationEUROPEAN STANDARDEN 61169-2NORME EUROPÉENNEEUROPÄISCHE NORMMarch 2007ICS 31.220.10Supersedes EN 61169-2:2001English versionRadio-frequency connectors - Part 2: Sectional specification -Radio frequency coaxial connectors of type 9,52(IEC 61169-2:2007)Connecteurs pour fréquences radioélectriques -Partie 2: Spécification intermédiaire - Connecteurs pour fréquences radioélectriques de série 9,52(CEI 61169-2:2007)Hochfrequenz-Steckverbinder - Teil 2: Rahmenspezifikation -Koaxiale HochfrequenzsteckverbinderTyp 9,52(IEC 61169-2:2007)This European Standard was approved by CENELEC on 2007-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.CENELECEuropean Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische NormungCentral Secretariat: rue de Stassart 35, B - 1050 Brussels© 2007 CENELEC -All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.Ref. No. EN 61169-2:2007 E 9 EN 61169-2:2007ForewordThe text of document 46F/56/FDIS, future edition 2 of IEC 61169-2, prepared by SC 46F, R.F. and microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61169-2 on 2007-03-01.This European Standard supersedes EN 61169-2:2001.The main change introduced in EN 61169-2:2007 is that the maximum frequency is now 3 GHz. The following dates were fixed: latest date by which the EN has to be implementedat national level by publication of an identicalnational standard or by endorsement(dop)2007-12-01 latest date by which the national standards conflicting with the EN have to be withdrawnAnnex ZA has been added by CENELEC.(dow)2010-03-01Endorsement noticeThe text of the International Standard IEC 61169-2:2007 was approved by CENELEC as a EuropeanStandard without any modification.CONTENTS1Scope . 42Normative references .43Interface dimensions .43.1Interface .43.2Mechanical gauges.84Quality assessment procedures. .94.1General. . 94.2Ratings and characteristics .94.3Test schedule and inspection requirements . 114.4Procedures .135Instructions for preparation of detail specifications . 135.1General .135.2Identification of the detail specification .135.3Identification of the component .145.4Performance.145.5Marking, ordering information and related matters .145.6Selection of tests, test conditions and severities .145.7Blank detail specification pro-forma for type 9,52 connector .15Annex ZA (normative) Normative references to international publications with theircorresponding European publications .20 Figure 1a Sliding male connector . 5Figure 1b Sliding female connector .5Figure 1 Sliding connector .5Figure 2a Screw coupling male connector . 6Figure 2b Screw coupling female connector . 6Figure 2 Screw coupling connector .6Figure 3a Standard test male connector .7Figure 3b Standard test female connector .7Figure 3 Standard test connectors .7Figure 4 Gauge pins for outer contact of socket connector .8Figure 5 Gauge pins for centre contact of socket connector . 9Table 1 Ratings and characteristics . 10Table 2 Acceptance tests . 11Table 3 Periodic tests . 12 RADIO-FREQUENCY CONNECTORS Part 2: Sectional specification Radio frequency coaxial connectors type 9,521ScopeThis part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors of type 9,52.It describes the interface dimensions for general purpose grade 2 connectors, dimensional details for standard test connectors, grade 0, together with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all DS relating to type 9,52 connectors.This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements.2Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.IEC 61169-1:1992, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods3Interface dimensions3.1Interface3.1.1GeneralAll dimensions are in millimetres.All undimensioned pictorial configurations are for reference purposes only.3.1.2DimensionsFigures 1, 2 and 3 provide dimensions for sliding connectors, screw coupling connectors and standard test connectors respectively.9,1 min.2,35 +0,030,08+0,431 +0,30,17,11 00,8 ± 0,42 max.8,5 min.9,525 ± 0,05Cone or radiusIEC 105/07Figure 1a Sliding male connector7,54 min.+1,50,5 0IEC 106/07Figure 1b Sliding female connectorFigure 1 Sliding connector+0,437,11 04 ± 0,54 min.Optional sealing gasketM14 × 1IEC 107/07Figure 2a Screw coupling male connectorM14 × 15 min.IEC 108/07Figure 2b Screw coupling female connectorFigure 2 Screw coupling connector9,1 min.2,35 ± 0,01+0,437,11 01 +0,30,10,8 ± 0,48,5 ± 0,022 max.4 min.9,525 ± 0,05M14 × 1IEC 109/07M14 × 1Figure 3a Standard test male connector7,54 min.7,2 min.5 min.+0,23,2 ± 0,020,5 04 slotswidth 0,3 mmlenght 4,5 mmIEC 110/07Figure 3b Standard test female connectorFigure 3 Standard test connectors3.2Mechanical gauges3.2.1GeneralAll dimensions are in millimetres.All undimensioned pictorial configurations are for reference purposes only.3.2.2Socket connectors Gauges for the resilient outer contactFigure 4 illustrates gauge pins for outer contacts of socket connectors.ab7 ± 0,5IEC 111/07Surface finish: Ra <=0,5W eight: 5 NReferenceGauge AGauge BmmmmMin.Max.Min.Max. a b9,5755,09,5855,29,4657,09,4757,2Test sequencea) Steel test pin (A) (Figure 4) shall be inserted at least three times into the outer contact. b) A second steel test pin (B) (Figure 4) shall be inserted into the outer contact.This gauge, when in a vertical downward attitude, shall be retained by the contact.Figure 4 Gauge pins for outer contact of socket connector3.2.3Socket connectors Gauges for the resilient centre contactFigure 5 illustrates gauge pins for centre contacts of socket connectors.5 +0,20aR0,500,1Surface finish: Ra <=0,5IEC 112/07ReferenceGauge CmmGauge DmmMin.Max.Min.Max. a2,382,392,292,30Test sequencea) Steel test pin (C) (Figure 5) shall be inserted at least three times into the centre contact. b) A second steel test pin (D) (Figure 5) shall be inserted into the centre contact.This gauge, when in a vertical downward attitude, shall be retained by the contact. This gauge will have a mass (weight) of 0,25 N.Figure 5 Gauge pins for centre contact of socket connector4Quality assessment procedures4.1GeneralThe following subclauses provide recommended ratings, performance and test conditions to be considered when writing a detail specification (DS). They also provide an appropriate schedule of tests with minimum levels of conformance inspection.4.2Ratings and characteristicsThe RF connectors defined in this standard are designed for use with a variety of flexible and semi-rigid coaxial cables and in microwave integrated circuits and similar uncabled applications. Table 1 lists the ratings and characteristics involved.Table 1 Ratings and characteristicsRatings and characteristicsIEC 61169-1 subclauseValueRemarksincluding an y deviations from standard test methodsElectricalNominal impedanceFrequency rangeReflection factor straight styles a right angle styles solder bucket and PCB mounting styleCentre contact resistance initial after conditioningOuter conductor continuity initial after conditioningInsulation resistance initial after conditioningProof voltage at sea level b cScreening effectivenessDischarge test (Corona)9.2.19.2.39.2.59.2.69.2.89.2.90-3 GHZ7% up to 2 GHZ10% up to 3 GHZ< 5 m< 10 m< 2,0 m< 2,5 m> 1 G> 1 M750 Vas 90 dBnaShall meet the requirements of9.2.1.1 of IEC 61169-1 when terminating a Zc = 75 cableSee DSSee DSUnder consideration86 kPa - 106 kPaZtMechanicalGauge retention force (resilient contacts) Contact