欢迎来到三一办公! | 帮助中心 三一办公31ppt.com(应用文档模板下载平台)
三一办公
全部分类
  • 办公文档>
  • PPT模板>
  • 建筑/施工/环境>
  • 毕业设计>
  • 工程图纸>
  • 教育教学>
  • 素材源码>
  • 生活休闲>
  • 临时分类>
  • ImageVerifierCode 换一换
    首页 三一办公 > 资源分类 > DOC文档下载  

    BS英国标准BS EN 5018611999 额定电压超过1KV的电力安装洗衣系统.一般要求.doc

    • 资源ID:5198624       资源大小:292KB        全文页数:9页
    • 资源格式: DOC        下载积分:10金币
    快捷下载 游客一键下载
    会员登录下载
    三方登录下载: 微信开放平台登录 QQ登录  
    下载资源需要10金币
    邮箱/手机:
    温馨提示:
    用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)
    支付方式: 支付宝    微信支付   
    验证码:   换一换

    加入VIP免费专享
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS英国标准BS EN 5018611999 额定电压超过1KV的电力安装洗衣系统.一般要求.doc

    BRITISH STANDARDLive-line washing systems for power installations with nominal voltages above 1 kV ÐPart 1: Common requirementsThe European Standard EN 50186-1:1998 has the status of aBritish StandardICS 29.260.10| BS EN50186-1:1999|NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBS EN 50186-1:1999National forewordThis British Standard is the English language version of EN 50186-1:1998, incorporating Corrigendum January 1999.The UK participation in its preparation was entrusted to Technical CommitteePEL/78, Tools for live working, which has the responsibility to:Ð aid enquirers to understand the text;Ð present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed;Ð monitor related international and European developments and promulgate them in the UK.A list of organizations represented on this committee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled ªInternational Standards Correspondence Indexº, or by using theªFindº facility of the BSI Standards Electronic Catalogue.A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application.Compliance with a British Standard does not of itself confer immunity from legal obligations.Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 5 and a back cover.Amd. No.DateText affectedThis British Standard, having been prepared under the direction of the ElectrotechnicalSector Committee, was published under the authority of the Standards Committee and comes into effect on 15 May 1999BSI 05-1999ISBN 0 580 32282 3Amendments issued since publicationEUROPEAN STANDARDEN 50186-1NORME EUROPE ENNEEUROPAÈ ISCHE NORMSeptember 1998incorporating Corrigendum, January 1999ICS 29.260.10Descriptors: electrical insulators, washing, cleaning, installation, electrical installation, utilization, safety, distanceEnglish versionLive-line washing systems for power installations with nominal voltages above 1 kV ÐPart 1: Common requirementsSysteÁ mes de lavage sous tension pour installations de puissance de tension nominale supe rieureaÁ 1 kV Ð Partie 1: Prescriptions ge ne ralesAbspritzeinrichtungen fuÈ r Starkstromanlagen mitNennspannungen uÈ ber 1 kV Ð Teil 1: Allgemeine AnforderungenThis European Standard was approved by CENELEC on 1997-03-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.CENELECEuropean Committee for Electrotechnical Standardization Comite Europe en de Normalisation Electrotechnique EuropaÈ isches Komitee fuÈ r Elektrotechnische NormungCentral Secretariat: rue de Stassart 35, B-1050 Brussels1998 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELECmembers.Ref. No. EN 50186-1:1998 EPage 5EN 50186-1:1998BSI 05-1999ForewordThis European Standard was prepared by theCENELEC BTTF 62-4, Live-line washing systems forContentsPagepower installations with rated voltages above 1 kV.The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50186-1on 1997-03-11.The following dates were fixed:Ð latest date by which the EN has to be implemented at national level by publication of an identical national standard or byendorsement (dop) 1999-03-01Ð latest date by which the national standards conflicting with theEN have to be withdrawn (dow) 1999-03-01Because of different national prescriptions and practices relating to protective distances, it was necessary to prepare a standard in two parts, i.e.:Ð EN 50186-1, Live-line washing systems for power installations with nominal voltages above 1 kV Ð Part 1: Common requirements;Ð EN 50186-2, Live-line washing systems for power installations with nominal voltages above 1 kV Ð Part 2: National annexes.Where EN 50186-1 contains the common European requirements, EN 50186-2 collates the particular national provisions, mainly resulting from different practices relating to resistivity of the water, water pressure and spray nozzles. The provisionsof EN 50186-2 therefore take precedence over EN 50186-1 in the concerned country.It is the intention that these national provisions, which result from national laws, regulations and national standards, will gradually disappear, which should lead, at the end, to a future standard with only common European requirements.Foreword 21Scope 32Normative references 33Definitions 34General requirements for washing systems 35Installation of fixed washing systems 46Installation of portable washing systems 47Operation of live-line washing systems 41 ScopeThis European Standard applies to the installation and operation of fixed and portable washing systems for the washing and cleaning of energized insulators on outdoor installations with voltages over 1 kV.2 Normative referencesThis European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard onlywhen incorporated in it by amendment or revision. For undated references, the latest edition of the publication referred to applies (including amendments).EN 50186-2:1997, Live-line washing systems for power installations with nominal voltages above 1 kV ÐPart 2: National annexes.EN 60071-2:1997, Insulation co-ordination Ð Part 2: Application Guide.(IEC 60071-2:1996)3 Definitions3.1fixed washing systemsystem in which the water supply pipes and nozzles are permanently installed close to the insulators to be cleaned, and which can be put into operation from a location outside the washing areas3.2portable live washing systemsystem in which parts of the water supply pipes and nozzle pipes with the nozzles are fully mobile and must be moved manually close to the insulators to becleaned3.3washing areazone within the range of the sprayed water3.4full jeta jet of water which is closed on issuing from a nozzle and which breaks up into individual drops at a certain distance from the nozzleA jet can be regarded as closed when it is as transparent as a glass rod when it issues from the nozzle.3.5spray jeta jet of water which, on issuing from a nozzle, is formed from a close sequence of individual drops of water making no contact with one another3.6full-jet nozzlea nozzle which produces a closed jet of water3.7spray nozzlea nozzle which directly produces a broken-up jet of water3.8nozzle pipea nozzle carrier3.9multi-purpose nozzle pipea nozzle carrier which can produce either a spray or a full jet4 General requirements for washing systems4.1 A washing system shall be installed and designed such that it neither causes a hazard to operating personnel, nor impairs the operational effectiveness of the electrical installation, and effectively cleans the insulators.4.2 It shall be possible to monitor and control washing systems from a location outside the washing areas.4.3 The minimum monitoring equipment shall comprise:a) a water pressure monitor;b) a water conductivity monitor.4.4 The minimum control equipment shall comprise:a) a manual method of interrupting the washing process in the event of any irregularity,e.g. flashover;b) a device to interrupt the washing process manually and/or automatically in the event of a rise of water conductivity above a specified value;c) a device to interrupt the washing process manually and/or automatically in the event of a drop of water pressure below a specified value.4.5 It shall be possible to confirm the calibration of the conductivity monitoring device by means of suitable test equipment.4.6 Pipelines, pumps, containers and fittings shall be manufactured from materials from which particles cannot become detached and block the nozzles(e.g. rust, lining).4.7 Nominal diameters of the pipes and nozzles shall be selected so that the insulator to be cleaned can receive and be cleaned with a sufficient amount of water.4.8 The water pressure at the pump shall be selected according to the types of nozzle used, the distance of the nozzles from the insulator to be cleaned, and the diameter and length of the pipes.4.9 Storage tanks or water supply networks shall be designed to provide the required amount of water for a specified number of cleaning operations.5 Installation of fixed washing systems5.1 All parts of washing equipment shall be arranged so that the distance between them and the energized parts of the installation is not less than the minimum distances specified in EN 60071-2.5.2 For fixed washing systems it shall be possible to simultaneously wash groups of insulators in close proximity.5.3 Nozzles and nozzle arrangements5.3.1 Only spray nozzles shall be used.5.3.2 The quantity, nominal diameter and arrangement of nozzles shall be selected such that every insulator can be completely and quickly cleaned. If particular wind forces and directions are to be taken into account, this shall be agreed between supplier and client when designing the installation.5.4 Pipelines and valves5.4.1 Metallic or electrically non-conductive (plastic)pipes may be used.5.4.2 Prior to initial operation of the washing system or after repair work, it shall be possible to flush every section in order to avoid blockages of the nozzles. This shall be done with the substation equipmentde-energized. Additionally, the tightness and correct arrangement of spray nozzles shall be checked by trial spraying.5.4.3 The pipes shall be filled up to the nozzle priorto washing, and the washing process started by means of quick action valves to ensure that a spray jet is formed by the nozzles immediately.5.4.4 It shall be possible to drain the complete system for maintenance and frost protection purposes by means of suitable drain valves.5.5 Water supply5.5.1 The pump suction pipe shall be provided with a filter if necessary.5.5.2 For larger live-line washing installations, it is recommended that the washing system be divided into groups.5.6 EarthingIf metal pipes are used for the pipelines, electrically conducting or non-conducting nozzles may be used. These pipelines shall be provided with a low-resistance connection to the earthing system of the electrical equipment. If electrically non-conducting pipes areused, electrically conducting nozzles shall be used, and these, together with the fittings in the pipeline, shall be connected to the earthing system.6 Installation of portable washing systems6.1 Nozzle pipes and nozzlesNozzle pipes with spray or full-jet nozzles may be used for washing. Multi-purpose nozzle pipes are allowed.6.2 Nozzle pipe operating stand6.2.1 If the nozzle pipe cannot be held securely by hand, a platform with a stand shall be provided on which the nozzle pipe can be secured while being freely manoeuvrable.6.2.2 The nozzle pipe, stand and platform shall be bonded together and connected to the substation earthing system.6.2.3 If the nozzle pipe is on a vehicle, a platform shall be provided on this vehicle for the nozzle pipe operator, and procedures adopted according to 6.2.1.7 Operation of live-line washing systems7.1 At temperatures of about or below 0 8C, washing systems may only be operated when freezing of the water in the pipelines and on the insulators is prevented. It shall be taken into account that spraying of the water will produce evaporation and thus a lowering of temperature.7.2 Only waterproof equipment may be washed. Especially, due to the risk of explosion, onlywaterproof lightning arresters may be washed whileenergized.7.3 Pipelines shall be filled and operated such that pressure surges are reduced to acceptable limits.7.4 On commencement of the washing process, the insulators to be cleaned shall be sprayed quickly with a sufficient quantity of water. Wherever possible, the underlying parts shall be cleaned first.7.5 In windy conditions, washing of the installation shall be initiated against the wind direction, so that neighbouring sections are not endangered by an insufficient admission of water.7.6 Large washing systems should be divided into electrically adjacent groups. Once commenced, the washing of

    注意事项

    本文(BS英国标准BS EN 5018611999 额定电压超过1KV的电力安装洗衣系统.一般要求.doc)为本站会员(sccc)主动上传,三一办公仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知三一办公(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    备案号:宁ICP备20000045号-2

    经营许可证:宁B2-20210002

    宁公网安备 64010402000987号

    三一办公
    收起
    展开