【BS英国标准】BS EN 6167222003 Electroacoustics. Sound level meters Pattern evaluation tests.doc
BRITISH STANDARD BS EN61672-2:2003Electroacoustics Sound level meters Part 2: Pattern evaluation testsThe European Standard EN 61672-2:2003 has the status of aBritish StandardICS 17.140.50 BS EN 61672-2:2003National forewordThis British Standard is the official English language version ofEN 61672-2:2003. It is identical with IEC 61672-2:2003. Together with part 1 supersedes BS EN 60651:1994 and BS EN 60804:2001 which are withdrawn.The UK participation in its preparation was entrusted to Technical CommitteeEPL/29, Electroacoustics, which has the responsibility to:aid enquirers to understand the text;present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed;monitor related international and European developments and promulgate them in the UK.A list of organizations represented on this committee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or ofBritish Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for their correct application.Compliance with a British Standard does not of itself confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on11 July 2003© BSI 11 July 2003ISBN 0 580 42224 0Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 41 and a back cover.The BSI copyright date displayed in this document indicates when the document was last issued.Amd. No.DateCommentsAmendments issued since publicationEUROPEAN STANDARDEN 61672-2NORME EUROPÉENNEEUROPÄISCHE NORMJune 2003ICS 17.140.50Supersedes EN 60651:1994 + A1:1994 + A2:2001 & EN 60804:2000English versionElectroacoustics Sound level metersPart 2: Pattern evaluation tests(IEC 61672-2:2003)Electroacoustique SonomètresPartie 2: Essais d'évaluation d'un modèle(CEI 61672-2:2003)Elektroakustik SchallpegelmesserTeil 2: Baumusterprüfungen(IEC 61672-2:2003)This European Standard was approved by CENELEC on 2003-06-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.CENELECEuropean Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische NormungCentral Secretariat: rue de Stassart 35, B - 1050 Brussels© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.Ref. No. EN 61672-2:2003 EPage 41EN 616722:2003ForewordThe text of document 29/532/FDIS, future edition 1 of IEC 61672-2, prepared by IEC TC 29, Electroacoustics, in cooperation with the International Organization of Legal Metrology (OILM), was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61672-2 on2003-06-01.This European Standard, in conjunction with EN 61672-1, supersedes EN 60651:1994 + A1:1994 + A2:2001 and EN 60804:2000.The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identicalnational standard or by endorsement(dop)2004-03-01 latest date by which the national standards conflictingwith the EN have to be withdrawn(dow)2006-06-01Annexes designated "normative" are part of the body of the standard. In this standard, annex A is normative.Annex ZA has been added by CENELEC.Endorsement noticeThe text of the International Standard IEC 61672-2:2003 was approved by CENELEC as a European Standard without any modification.CONTENTS1Scope . 52Normative references. 53Terms and definitions . 64Submission for testing . 65Marking of the sound level meter and information in the instruction manual . 66Mandatory facilities and general requirements . 77Environmental, electrostatic and radio-frequency tests . 97.1General . 97.2Expanded uncertainties for measurements of environmental test conditions . 107.3Influence of static pressure . 107.4Tolerance limits on air temperature, relative humidity and static pressure . 117.5Acclimatization requirements for tests of the influence of air temperature andrelative humidity . 117.6Abbreviated test of the influence of air temperature and relative humiditycombined. 127.7Influence of air temperature . 147.8Influence of relative humidity. 157.9Influence of electrostatic discharges . 167.10 Influence of a.c. power frequency and radio-frequency fields . 168Radio-frequency emissions and public power supply disturbances . 209Electroacoustical performance tests . 219.1General . 219.2Indication at the calibration check frequency . 219.3Directional response . 229.4Tests of frequency weightings with acoustical signals . 249.5Tests of frequency weightings with electrical signals . 279.6Combined effect of reflections, diffraction and corrections for nominalmicrophone frequency response and for the influence of a windscreen . 299.7Adjustments to obtain free-field sound levels . 299.8Level linearity . 309.9Under-range indication. 329.10 Self-generated noise. 329.11 Decay time constants for time weightings F and S . 339.12 Toneburst response for sound level meters that measure time-weightedsound level . 339.13 Toneburst response for sound level meters that measure sound exposurelevel or time-average sound level . 349.14 Response to sequences of repeated tonebursts for sound level meters thatmeasure time-average sound level. 359.15 Overload indication . 369.16 Peak C sound level . 379.17 Reset . 389.18 Electrical output . 389.19 Timing facilities . 389.20 Crosstalk in multi-channel sound level meter systems . 389.21 Power supply . 3810 Pattern evaluation report . 39Annex ZA (normative) Normative references to international publications with theircorresponding European publications . 40ELECTROACOUSTICS SOUND LEVEL METERS Part 2: Pattern evaluation tests1 ScopeThis part of IEC 61672 provides details of the tests necessary to verify conformance to all mandatory specifications given in IEC 61672-1:2002 for conventional sound level meters, integrating-averaging sound level meters and integrating sound level meters. Pattern evaluation tests apply for each channel of a multi-channel sound level meter, as appropriate. Tests and test methods are applicable to class 1 and class 2 sound level meters. The aim is to ensure that all testing laboratories use consistent methods to perform pattern evaluation tests.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.IEC 60942, Electroacoustics Sound calibratorsIEC 61000-4-2:2001, Electromagnetic compatibility (EMC) Part 4-2: Testing and measure- ment techniques Electrostatic discharge immunity test Basic EMC Publication1IEC 61000-4-3:2002, Electromagnetic compatibility (EMC) Part 4-3: Testing and measure- ment techniques Radiated, radio-frequency, electromagnetic field immunity test Basic EMC Publication2IEC 61000-4-6:2001, Electromagnetic compatibility (EMC) Part 4-6: Testing and measure- ment techniques Immunity to conducted disturbances, induced by radio-frequency fields Basic EMC Publication3IEC 61000-6-2:1999, Electromagnetic compatibility (EMC) Part 6-2: Generic standards Immunity for industrial environmentsIEC 61094-1, Measurement microphones Part 1: Specifications for laboratory standard microphonesIEC 61183, Electroacoustics Random-incidence and diffuse-field calibration of sound level metersIEC 61672-1:2002, Electroacoustics Sound level meters Part 1: Specifications1 Edition 1.2 consisting of Edition 1:1995 consolidated with amendments 1:1998 and 2:2000.2 Edition 2.1 consisting of Edition 2:2002 consolidated with amendment 1:2002.3 Edition 1.1 consisting of Edition 1:1996 consolidated with amendment 1:2000.CISPR 16-1:1999, Specification for radio disturbance and immunity measuring apparatus and methods Part 1: Radio disturbance and immunity measuring apparatus 4CISPR 22:1997, Information technology equipment Radio disturbance characteristics Limits and methods of measurementISO Express Guide, Guide to the expression of uncertainty in measurementISO/IEC, International vocabulary of basic and general terms in metrology3 Terms and definitionsFor the purposes of this standard, in addition to the terms and definitions given in IEC 61672-1, thetermsanddefinitionsgiveninIEC61000-4-2:2001,IEC 61000-4-3:2002,IEC61000-4-6:2001, the Guide to the expression of uncertainty in measurement and theInternational vocabulary of basic and general terms in metrology also apply.4 Submission for testing4.1At least three specimens of the same pattern of sound level meter shall be submitted for pattern evaluation testing. As a minimum, the testing laboratory shall select two of the specimens for testing. At least one of the two specimens shall then be tested fully according to the procedures of this standard. The testing laboratory shall decide whether the full tests shall also be performed on the second specimen or whether limited testing is adequate to approve the pattern.4.2An instruction manual and all items or accessories that are identified in the instruction manual as integral components for the normal mode of operation shall be submitted along with the sound level meters. Examples of additional items or accessories include a microphone extension device or cable and peripheral equipment.4.3If the manufacturer of the sound level meter supplies devices that are to be co