欢迎来到三一办公! | 帮助中心 三一办公31ppt.com(应用文档模板下载平台)
三一办公
全部分类
  • 办公文档>
  • PPT模板>
  • 建筑/施工/环境>
  • 毕业设计>
  • 工程图纸>
  • 教育教学>
  • 素材源码>
  • 生活休闲>
  • 临时分类>
  • ImageVerifierCode 换一换
    首页 三一办公 > 资源分类 > DOC文档下载  

    RS矢网特点.doc

    • 资源ID:5184385       资源大小:111.50KB        全文页数:7页
    • 资源格式: DOC        下载积分:10金币
    快捷下载 游客一键下载
    会员登录下载
    三方登录下载: 微信开放平台登录 QQ登录  
    下载资源需要10金币
    邮箱/手机:
    温馨提示:
    用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)
    支付方式: 支付宝    微信支付   
    验证码:   换一换

    加入VIP免费专享
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    RS矢网特点.doc

    CharacteristicsThe family comprises the five Vector Network Analyzers ZVRL, ZVRE and ZVR as well as ZVCE and ZVC which extend the frequency range to 8 GHz. All models are compact instruments with integrated generator, test set and receiver, each tailored to a different field of application. All analyzers can be subsequently upgraded to the higher-class models. ZVRE and ZVCE : the economy modelsThe test set of these models comprises two SWR bridges (ZVRE) or directional couplers (ZVCE), an RF switch, two measurement channels and one reference channel. They measure the magnitude and phase of all four S-parameters of a DUT, allow a full two-port calibration (TOSM) and have an exceptionally high accuracy and wide dynamic range. - ZVRE, ZVCE (bidirectional, 3 channels) - ZVR and ZVC : the universal modelsZVR and ZVC comprise a test set with two SWR bridges (ZVR) or directional couplers (ZVC), an RF switch, two measurement channels and - unlike ZVRE and ZVCE - two reference channels. With this configuration a variety of novel calibration procedures, eg TNA, can be performed, which considerably improve the accuracy particularly in non-coaxial applications. ZVR and ZVC are the allrounders of the family and suitable for applications in R&D and production no matter how sophisticated.- ZVR, ZVC (bidirectional, 4 channels) - Test setsThe network analyzers can be provided with different test set options so that an optimally configured test setup is available to suit the applications.For the 4 GHz analyzers "active" or "passive" test sets with a characteristic impedance of 50 W or 75 W are available. A 50 W passive test set is standard equipment. With active test sets, the DUT can be biased directly via the inner conductor of the test port. The 8 GHz models ZVCE and ZVC are always equipped with 50 W active test sets. Depending on the model, the test sets comprise one or two power splitters, an electronic switch and one or two SWR bridges or directional couplers. Additional step attenuators (0 dB to 70 dB, components marked red in the drawings below) can be inserted into the generator paths and the two measurement channels to extend the power range of the receivers to +27 dBm and to lower minimum output power to -95 dBm. When the test sets are fitted with attenuators and the External Measurements option (components marked green in the drawings below), generator and receiver can be alternatively switched to three ports on the front panel (OUTPUT a1, INPUT b1, INPUT b2). This increases output power, sensitivity and dynamic range, and measurements down to 10 Hz can be performed with the 4 GHz models. In addition, the flexibility on external test sets, e.g. using an external pre-amplifier, is enhanced. The Reference Channel Ports (components marked blue in the drawings below) allow to feed the signal for the reference channel a1 from outside. This feature facilitates e.g. phase measurements on frequency converting devices. The test ports are fitted with female N connectors.Overview The vector network analyzers of the ZVR family from Rohde&Schwarz have set standards for extremely fast, highly accurate and versatile test equipment.The family comprises the five Vector Network Analyzers ZVRL, ZVRE and ZVR as well as ZVCE and ZVC which extend the frequency range to 8 GHz. All models are compact instruments with integrated generator, test set and receiver, each tailored to a different field of application.Thanks to the great variety of options and test sets, the analyzers can be tailored even to very special kinds of measurement tasks. In contrast to passive SWR bridges/couplers active SWR bridges/couplers contain a bias network, eg for supplying amplifiers. ModelZVREZVRZVCEZVCTest setbidirectionalReceiver channels3434Wide frequency range10 Hz1) to 4 GHz20 kHz to 8 GHzWide dynamic range1)>125 dB>130 dB>125 dB>130 dBHigh sensitivity1)<-125 dBm<-130 dBm<-125 dBm<-130 dBmHigh measurement speed<125 µs/pointFast IEC/IEEE bus2<15 msHigh frequency resolution10 µHzShort calibration times3)<20sLarge displayactive 26 cm colour LCD1) With External Measurements option.2) From marker request to data output (real and imaginary values).3) Automatic two-port calibration with AutoKal option. Features · Excellent dynamic range>130 dB (IF bandwidth 10 Hz)· Low inherent noise<-130 dBm (measurement bandwidth 3 kHz)· Broad frequency range for universal use10 Hz to 4 GHz (ZVRE, ZVR)20 kHz to 8 GHz (ZVCE, ZVC)· High measurement speed<125 µs/point (normalized)<240 µs/point (fully calibrated)· Fast data transfer via IEC/IEEE busTransfer time <15ms (200 points)· Customized, upgradable family conceptModular design using options· High sweep rate>>25 sweeps/s (200 points)· Manual calibration techniquesTOM, TRM, TRL, TNA, TOM-X, TOSM· Automatic calibration AutoKal· Compatibility with PC, CAEInternal PC with Windows NT operating system suitable for PC applicationsSpeed >>25 sweeps/sThe extremely low-noise and fast synthesizer in conjunction with an exceptionally large measurement bandwidth of up t o 26 kHz al l ows real - time result display. The ZVx measures not in two subsequent sweeps but at every frequency point in forward and backward direction and thus all four S-parameters - including system error correction. This ensures real-time display of fully corrected data even during alignments with reduced sweep speeds. The dynamic range of ZVx is more than 95 dB even at a high measurement rate of 25 sweeps/s and 10 kHz measurement bandwidth.Dynamic range >130 dBThe high stopband and low passband attenuation of modern RF components place new demands on network analyzers. Thanks to fundamental mixing, the useful dynamic range of Rohde & Schwarz network analyzers is more than 25 dB better than with conventional sampling techniques. Because of the low-noise front end, Rohde & Schwarz network analyzers attain a dynamic range of >130 dB, so transmission measurements on DUTs with extremely high stopband attenuation can be performed with high accuracy, even at low input levels.Power calibration: testing active DUTsPower calibration performed in the factory enables constant output power and high accuracy in the measurement of absolute input level over the full frequency range. This is particularly important for frequency-converting measurements and non-linear measurements on active components. Furthermore, frequency-dependent level variations of an external test setup can be measured and compensated with the aid of the Power Calibration option. Simultaneous display of four traces on the 26 cm colour LCDThe ZVx models are the first network analyzers in this price class to simultaneously display up to four measurement traces with independent parameters (measured quantity, frequency range, bandwidth, etc). The large, active colour LCD with high refresh rate allows precise alignments without operator fatigue.Internal PCThe network analyzers are equipped with a PC board including interfaces for keyboard, mouse, printer, external monitor and WindowsNT as the operating system. In the PC mode, the internal hard disk can be accessed and PC programs executed on the ZVR. This function considerably simplifies operation, processing and result recording. The optional Ethernet link, the integration of any printer driver and the execution of IEC/IEEE bus control programs on ZVR considerably extend the applicationrange and performance. Complete setups, traces, numerical results, limit lines, calibration data, macros and screenshots can be stored on the hard disk or on floppy disks. The available formats (e.g. WMF, ASCII, Serenade.) allow problem-free import to Windows programs. The data can be processed in the ZVR with the aid ofthe internal PC.Automatic test systemsFast recording and processing of measured data and, in addition, an SCPI-conformal IEC/IEEE bus command set make all models of the ZVR family ideal for use in automatic measurement systems. All models are equipped with two IEC/IEEE bus interfaces as standard. One is used for analyzer control via an external PC, the other for controlling external devices, e.g. signal sources for intermodulation or mixer measurements, from the ZVR. Another optional IEC/IEEE bus interface is provided for the internal PC. Via this interface, IEC/IEEE control programs can be executed on the internal PC, thus enabling the ZVR to control itself or complete test systems. The Ethernet option allows data exchange and control via LAN.Efficient calibration techniquesThe classic 12-term calibration method requires four calibration standards: Through, Open, Short and Match. The name TOSM given to this method is an abbreviation of the standards' names. A number of other modern calibration methods (TOM, TRM, TRL, TNA) are also provided in ZVR and ZVC. Unlike TOSM (12-term) they require only three different standards. Additionally, lines (L), reflecting one-ports with unknown reflection coefficient (R), matched attenuators (A) and two-port networks (N) with symmetrical reflection can be used. Due to its simplicity, TOM is the method recommended for general applications. For calibration at frequencies up to 100 MHz it is noteven necessary to connect an open circuit, and the ports may simply be left open. Thus a complete two-port calibration can be performed with only two calibration standards. TOM allows also implicit verification so that errors caused by defective calibration kits or operating errors are excluded. This considerably enhances reliability in the laboratory and particularly in production.With on-wafer measurements, measurements on PCBs or in fixtures it is difficult to design or specify suitable calibration standards at justifiable effort. This problem can be solved with the TNA and TRM calibration methods developed and patented by Rohde& Schwarz. With these methods the characteristics of the calibration standards need not be fully known. With TNA, for instance, a full two-port calibration can be performed with two standards: if reflection symmetry is provided at the reference planes, the calibration step with network (N) does not require a standard to be connected, the test ports can just be let open. Just a through (T) with known length and a matched attenuator (A) are required.The calibration effort is reduced to a minimum when the AutoKal option is used that requires only one simple through-connection.

    注意事项

    本文(RS矢网特点.doc)为本站会员(sccc)主动上传,三一办公仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知三一办公(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    备案号:宁ICP备20000045号-2

    经营许可证:宁B2-20210002

    宁公网安备 64010402000987号

    三一办公
    收起
    展开