d630MW超临界机组事故处理措施.doc
First compliance review of the application of the appraisal Committee, only through the compliance review of the application to take part in a detailed review. 8.1 application compliance review: does not meet one of the following conditions, procuratorial Agency to submit application through compliance reviews, be invalidated: (1) application of the formats, contents, meet the requirements of selected files, powers of Attorney, declarations by the legal representative and the tender agent application to meet the requirements; (2) licence and a bidding agent qualifications meet the requirements; (3) the similar project tendering agency agent number and provide proof of material compliance; (4) the tendering Agency intends to put into this project the number of professionals to meet the requirements; (5) are intended to the agent of the project as a project manager has similar projects the number of and references to meet the requirements; (6) no fraud case. 8.2 application review in detail the Evaluation Committee through compliance reviews will be selected for detailed review of the application. 8.2.1 tender agent institutions similar project tender performance requirements (16 points) tender agent institutions similar project tender performance 16 points, by two part composition (1) agent similar project of cumulative bid amount scored calculation rules for: Agent water project bid amount (on January 1, 2007 has has bid notice for associate) cumulative each reached 100 million Yuan have 2 points, water project cumulative bid amount scored up not over 6 points. In addition, completes a bid worth more than 500 million yuan in total 1 minute, but other items score accumulated winning amount up to a maximum of 6 points. (2) calculation rule for the number of agents similar projects: proxy bid amount (since January 1, 2007 winning notice shall prevail) bidding projects in more than 50 million Yuan by 2 points, but the Agency projects the number of scores up to 3 minutes. 8.2.2 to be agents of the construction project as a project manager in the same project performance (10 points) Project Manager agent performance scores including agents of the bidding agencies of similar projects, as well as in other similar project tendering agency service agent during performance. Total 10 Project Manager agent performance, made up of two parts (1) acting like the accumulated winning amount calculation rule: agents for water conservancy project bid amount (since January 1, 2007 winning notice for example) cumulative average reached 100 million Yuan 3 but scored no more than 5 minutes. (2) calculation rule for the number of agents similar projects: proxy bid amount (since January 1, 2007 winning notice for example) in the more than 50 million Yuan water conservancy project period of 3 minutes, but scores the number of agents similar projects up to a maximum of 5 points. Project Manager demonstrated to provincial-level and higher people's Government or the development and Reform Commission published the winning bidder on the designated media publicity shall prevail. 8.2.3 staff requirement (25 points) 1, to the construction project serving personnel, 4 years experience in tendering agent, 2 points per person, 2 years experience in tendering agent .Pig is not a pig. With domestic international market and technology big environment of changes, as China traditional industry of pig production of job way and profit way are requirements related industry for resources integration, to quality security for premise, regulation based farming, and management cost and the production, and sales cost, go standardization, and scale, and intensive, and market road, fast upgrade whole industry chain of regulation capacity, market competition capacity and anti-risk capacity. First, industry analysis (a) the basic situation in China is a traditional hog production and consumption country, 2008 46.15 million tons of pork, pig stock 462.64 million head by the end pig slaughter 609.6 million. National pig industry's annual production value at around 650 billion yuan, nearly 50% per cent of annual output value of animal husbandry. Sichuan province in 2008 produced 6.52 million tons of pork, with 694,000 tons of Chengdu city, live pig sell 10.46 million, first 15 Vice-provincial cities in the country. The whole nation advantage regional planning (2008-2015) there are 437 counties (cities), 55, Sichuan, Chengdu has 7 (including in pengzhou). International pig industry mainly include the European Union, the United States, and Canada, and Brazil and other absolute scale of animal husbandry industry and technology developed countries. Market 1, the domestic market from China's meat consumption habits and economic analysis of the development situation, the emergence of new trends in the market of domestic pork and its products. Docking is a pig production and sales more closely. The Yangtze River Delta, Pearl River Delta and the Bohai rim economic developed area industrial structure adjustment gathered pace, two or three industries to the Central and Western bias. Second, the rigid domestic consumption growth. For a long period, pork is still the largest variety of meat consumption in China, the absolute consumption continues to grow. Especially in the vast rural market growth potential. Third, market for pork and higher product quality requirements. Pollution-free pork safety and health has shown a very good market prospects. Four is the market changing. Currently, cold meat, more and more varieties of meat and pork meat products, which accounted for a large proportion of pork consumption, stores, chain stores, supermarkets and other marketing methods is on the rise, and transport has been extended to more than 2000 km in RADIUS. Chengdu is an important "River pig" resource market, the city's commercial rate reaches above 60% of live pigs, pork and raw materials primary processing products in the domestic and international reputation is high. Western hog trading center in Chengdu and provides disease-free areas of construction in order to further accelerate the development of swine industry realizes space and conditions. 2, the international markets at present, annual volume of trade in live pigs in the world year around 18 million, about 6 million tons of pork trade. A large net exporter of pork is mainly the EU and North America,-importing countries mainly in Asia, Japan, and Korea, and Singapore, the Philippines, Hong Kong and other countries and regions, as well as Russia, about 3 million tonnes were imported. It is predicted that the world meat consumption increase of 80% in Asia in the future, our country has obvious geographical advantages, export potential. With the advancement of live pigs superiority industry belt construction, animal disease .引风机跳闸处理措施1、 确认单侧引风机跳闸,引风机进口挡板联关,否则手动关闭。将跳闸引风机进口静叶全关。2、 RB保护应动作,否则手动执行RB程序:顺序跳闸C、E、D磨煤机,控制负荷300MW,总煤量160t/h。3、 检查同侧送风机联跳,出口挡板关闭,联络门联开正常。4、 解除运行引风机转速自动,手动加大出力,调整炉膛负压正常。5、 解除运行送风机转速自动,手动调整出力,防止送风机过负荷。6、 注意调整炉膛负压、氧量、两侧烟温差、主、再热汽温、煤水比正常。7、 协调切至手动方式,根据氧量调整机组负荷。8、 燃烧不稳时投入点火油枪、等离子稳燃。9、 注意控制运行送、引风机不超额定电流,加强对运行送、引风机的运行监视、检查。10、 若A、B引风机同时跳闸,按MFT动作处理。送风机跳闸处理措施1、单侧送风机跳闸,RB保护动作,出口挡板关闭,联络门联开,运行的C、E、D磨煤机跳闸,进、出口挡板关闭,否则手动RB。2、立即解除送风机自动,加大运行送风机出力,调整氧量3%以上。3、立即手动减少给水量,保证分离器出口过热度5以上,注意控制炉膛负压、汽温、煤水比正常。4、协调切至手动方式,降负荷至50-60%额定负荷。5、燃烧不稳时投入点火油枪、等离子稳燃。6、注意监视运行送风机不超额定电流,或根据运行送风机出力(氧量)带负荷。并加强对运行风机的检查,防止运行送风机过流跳闸。8、检查送风机跳闸原因,尽快恢复运行。9、各主要参数控制正常,汽温、汽压、煤水比、两侧烟温差控制在规定范围内。10、若A、B送风机同时跳闸,按MFT动作处理。一次风机跳闸处理措施1、 单侧一次风机跳闸,RB保护动作,检查跳闸的一次风机出口挡板关闭,联络门联开,运行的C、E、D磨煤机跳闸,进、出口挡板关闭,否则手动RB。2、立即解除一次风机自动,加大运行一次风机出力,调整一次风压至7.0kPa左右,维持三台底层磨煤机运行。3、解除机组协调,手动控制负荷在240MW左右,总煤量不大于120t/h。4、燃烧不稳时,投入点火油枪、等离子稳燃。5、加强运行磨煤机状态监视、调整,增加排渣频次,防止堵磨。6、 注意监视运行一次风机不超额定电流256A,或根据运行磨煤机状态,调整煤量、负荷。7、事故处理过程中,注意停磨速度,防止磨煤机堵煤或一次风管堵塞,造成事故扩大。8、监视脱硝装置入口烟温,及时退出脱硝装置运行。9、控制汽温、汽压、煤水比、两侧烟温差等主要参数在规定范围内。10、若A、B一次风机同时跳闸或单侧一次风机跳闸造成锅炉灭火,按MFT动作处理。空预器跳闸处理措施1、 空预器主马达跳闸,检查辅马达或气动马达联启。若联启不成功,手动启动辅助或气动马达,否则人工盘车。2、 空预器跳闸时,联跳同侧送、引风机,RB保护动作,运行的C、E、D磨煤机跳闸,冷、热风插板门、出口插板门关闭。3、 检查跳闸侧SCR入口烟气挡板、空预器出口热一、二次风挡板、送风机出口联络门联关;热二次风联络门、一次风机出口联络门联开。检查跳闸送风机出口挡板、引风机入口挡板联关,将跳闸送风机动叶、引风机静叶全关。4、 手动调整运行风机出力,控制送风机、引风机电流不超限。引风机变频运行时,手动调整变频转速,调整炉膛压力正常。5、 手动关闭跳闸侧脱硝装置供氨快关阀,关闭其供氨手动门。6、 调整两台一次风机出力平衡,防止抢风。如燃烧不稳,投油稳燃。7、 停止跳闸空预器吹灰。8、 空预器跳闸后热一次风温降低,加强磨煤机出口温度监视,必要时投入A磨煤机暖风器。9、 若跳闸空预器进出口隔离门、联络门关闭不严密无法隔离,或空预器气动马达及手动盘车均无法盘动,出口烟温不正常上升至250,紧急停炉。10、 若单侧空预器跳闸造成锅炉MFT动作或两台空预器同时跳闸,按机组MFT动作处理。SCR氨逃逸率超标处理措施1、运行中控制脱硝出口氨逃逸率小于2.28ppm。在锅炉负荷及脱硝系统运行方式未发生变化的情况下出现反应器出口氨逃逸率超标,应减少喷氨量,观察SCR 反应器出口氨逃逸率,如果氨逃逸率无变化,则判断为氨逃逸表计故障,联系热控人员处理。2、检查SCR 反应器出/入口NOx测点,如测点故障导致喷氨量过大,立即减小脱硝效率设定值,联系热控人员处理NOx测点,使其尽快恢复正常。3、检查氨流量测点,防止测点偏小,导致喷氨量偏差过大。4、如排除热控测点原因,则对喷氨系统系统进行检查,核对喷氨分配支管手动门开度,防止局部喷氨量过大。5、检查供氨温度是否过低,如供氨温度接近饱和温度,及时投运供氨管道蒸汽伴热。6、启停磨煤机后,应及时调整氧量两侧平衡,保持SCR入口A、B侧氮氧化物尽可能一致,尽量保持两侧反应器出口NOx排放量相同。7、氨逃逸率合格之前,加强空预器差压监测,增加空预器吹灰频次,防止空预器堵塞。事故处理原则1、 发生事故时,遵照“保人身、保设备、保电网”的原则,各岗位根据各自的职责迅速按规程规定正确处理事故。2、 发生事故时,应迅速弄清事故首发原因,消除对人身和设备安全的威胁,保证非故障设备运行,防止事故扩大。任何情况下应尽量保证厂用电不失去。3、 事故发生时,报警信号可确认,不允许立即复归,待详细记录报警信号后方可复归。4、 当判明是系统发生故障时,则应采取措施,维持各辅助系统正常运行,以便有可能尽快恢复整套机组的正常运行。5、 事故处理时,各岗位应及时互通情况,在值长、主值统一指挥下,密切配合,迅速处理。6、 当发生规程以外的事故时,值班人员应根据经验作出正确判断,主动采取对策,迅速处理。7、 事故处理中,达到主、辅机紧急停运条件而保护未动作时,应立即手动打闸。8、 若出现机组突然跳闸情况,事故处理完后,事故原因已查清并消除后,应尽快恢复机组运行。9、 如果事故处理发生在交接班时间,应延期交班。接班人员应主动协助进行事故处理。10、 事故处理完毕,值班人员应立刻如实汇报并做好记录。班后组织人员进行分析,并写报告。DCS失电处理措施1、 当全部操作员站故障时(所有上位机“黑屏”或“死机”),应立即停机、停炉。2、 当部分操作员站故障时,由可用操作员站继续承担机组监控任务,停止重大操作,同时通知热工人员处理。3、 DCS失电停机时,立即从手操盘上启动交流润滑油泵,否则启动直流油泵,并开启真空破坏门破坏真空。4、 就地控制柜上启动空侧直流油泵,检查密封油系统运行正常。5、 润滑油系统运行正常时,当汽机转速降至600r/min时,就地启动顶轴油泵。6、 就地监视除氧器水位,水位过高时,手动开启除氧器底部放水门控制水位,必要时停止凝结水泵运行,防止满水。7、 就地监视凝汽器水位,水位过高时,关闭凝汽器补水门,必要时开启凝泵出口放水门放水,防止凝汽器水位高造成真空泵进水。8、 如电泵运行时立即到就地启动电泵辅助油泵,然后就地停止电泵,防止电泵损坏。9、 如短时间内DCS电源不能恢复,根据情况到就地停止其它转动设备,原则上做到不损害设备。10、 加强对DCS系统的监视检查,特别是发现网络、模件、电源等故障时,及时通知热工人员,做好相应对策。厂用电全部失去处理措施1、 检查高中压主汽门、调门、高排逆止门、各抽汽逆止门已关闭,否则手动关闭,汽机转速下降。2、 确认主机、小机直流油泵、直流密封油泵均已启动,否则可手动强合两次,强合不成功迅速查明原因处理后启动。检查主机润滑油压、油氢差压正常。3、 检查柴油发电机自启动成功,否则手启,以保证保安段的正常供电。4、 关闭炉前燃油进回油手动门,在厂用电恢复前,严禁向凝汽器排汽水。5、 检查发电机励磁开关、6kV及400V所有开关在“分”位,否则手动拉开。6、 检查制粉系统的风门、挡板位置正确,过、再热器喷水隔离门关闭。7、 逐步恢复机组保安PC和机、炉保安MCC电源及交流事故照明正常电源。8、 启动主机交流润滑油泵、顶轴油泵、交流密封油泵,小机主油泵、EH油泵、盘车电机,空气预热器辅助电机、空气预热器油站和火检冷却风机等。9、 检查UPS正常,电源切换正常。投入直流系统的浮充装置,停用有关的直流设备。10、 主机转速至零时投入连续盘车。如投盘车前转子已静止,先翻转转子180°,再投入连续盘车。6kV工作电源开关跳闸处理措施1、 厂用6kV单段母线失电后,应立即查看机组RB动作正常,手动调整运行侧一次风机、送、引风机出力,防止炉膛总风量低或炉膛负压波动大锅炉MFT。2、 若6kV单段母线失电后,引起锅炉熄火,检查锅炉MFT动作,否则手动MFT,切断所有燃料。3、 检查6kV失压母线上设备开关低电压保护动作跳闸,否则手动拉开。4、 检查6kV、380V各备用辅机联启,否则手动启动;若运行的磨煤机仅剩2台,视情况增启磨煤机。5、 6kV母线失电后,手动拉开锅炉变、汽机变、电除尘变、照明变、检修变高低压侧开关。6、 检查跳闸送、引、一次风机的挡板及动、静叶、磨煤机冷、热风挡板关闭,否则手动关闭。7、 调整给水流量及主、再热汽温,防止汽温大幅波动。8、 检查锅炉氧量、负压在规定范围内,应切为手动调整。9、 加强对运行引、送、一次风机的监视,防止其过负荷。10、 汽机降负荷时,要加强胀差、轴向位移、轴承及轴的振动、推力瓦和支持瓦温度的监视。直流接地处理措施1、 测量直流接地对地绝缘,判别接地极性及接地性质。2、 直流接地时,检查有无启停设备,首先对刚启动设备进行试拉。3、 检查有人是否在直流回路上工作,造成人为接地,直流接地时禁止在二次回路上工作。4、 拉试可疑负荷前要通知用户并取得同意并汇报值长后方可进行。5、 拉试直流接地要有维护人员现场配合。6、 禁止对热控直流电源进行拉试,热工控制回路直流接地的查找在任何时候都由热控人员进行。7、 保护用直流电源不允许自行拉试,要在维护人员按照批准的技术措施执行并汇报专工、值长、副总后方可操作。8、 若采用拉试法查找接地点时无论回路是否接地,判断后立即恢复供电。9、 直流母线接地期间,禁止任何的直流母线倒换、并列操作。10、 接地点确认后尽快隔离,保证直流系统的正常运行。锅炉A变跳闸处理措施1、 检查锅炉A变跳闸,锅炉PC A、B段联络开关已联动合闸。2、 检查锅炉保安MCC、锅炉MCC电源已由电源一切至电源二供电正常。3、 立即解除机组协调控制,手动控制机组负荷、主、再热汽温正常,投入F层点火油枪稳定燃烧。4、 检查空空预器辅助马达联启正常,否则手动启动辅助马达。5、 复位六台磨煤机液压油泵,复位后如显示在分闸位置,手动启动六台磨煤机液压油泵。6、 检查六台风机油站,运行油泵跳闸,备用油泵联启正常,否则手动启动六台风机油站。7、 检查A、B、C给煤机跳闸,根据机组负荷及主汽温,手动启动三台给煤机,否则按机组RB处理。8、 就地检查锅炉A变高压开关保护动作信息。9、 将锅炉A变由热备用状态转检修状态,对变压器进行检查处理。10、 处理正常后,将锅炉A变恢复正常供电方式。发电机2PT二次电压消失处理措施1、 检查发电机有、无功负荷指示降低或至零;定子电压指示到零;高厂变、高硫变有功指示到零。2、 检查发变组保护B柜发“TV”报警信号发出。3、 检查自动励磁调节器由通道自动切至通道自动运行稳定。4、 立即解除AGC和一次调频,手动解除机组协调,稳定机组负荷在当前值,可以参照主变出口有功调节。5、 检查发变组保护A柜运行正常。6、 检查发电机PT二次侧是否有人工作引起的二次小空开误跳,如误跳则手动合闸,检查发电机各项参数恢复至正常值。7、 检查发电机PT二次空开不是因误跳引起的,立即退出发变组保护B柜所有保护。8、 检查2PT一、二次回路,如保险熔断,立即更换。如二次自动开关跳闸,检查无明显故障,立即试送一次。9、 试送成功后,复归自动电压调节器报警信号,检查自动电压调节器通道跟踪良好。10、 试送成功后,检查发变组保护B柜无异常信号,按照正常方式投入发变组保护B柜各压板。交流接地处理措施1、 立即检查核对该低厂变低压侧所带的负荷有无自动或手动启动的设备。2、 检查有设备启动则切换方式停运该设备并检查接地现象是否消失,若消失则对该设备进行就地检查并联系处理。3、 确认无设备启动或非设备启动引起接地,则对发生接地的母线用万用表进行相间电压和相对地电压的测量,确认接地相和接地程度。4、 同时检查小电流接地系统选线装置的报警信息,查看接地信息,判断接地情况。5、 若为负荷接地,则对小电流选线装置指出的负荷进行拉试确认(拉试前调整运行方式)。6、 若所有负荷都无接地情况则检查变压器低压侧和PC母线是否有接地点。7、 若为变压器低压侧接地,则请示值长停用变压器,母线由联络开关供电。8、 若为母线接地,则需转移负荷,停用母线,联系检修进行处理。9、 交流接地运行时间不得超过2小时。10、 交流接地处理完毕后及时恢复设备正常运行。汽泵跳闸处理措施1、 确认跳闸小机中、低压主汽门、调门关闭,四抽进汽及冷段进汽电动门已关闭,小机转速下降。2、 确认电泵组联锁启动,否则手启电泵,快速提高电泵转速,防止给水流量过低,检查运行汽泵正常。3、 检查跳闸汽泵出口电动门、中间抽头电动门关闭、最小流量阀开启,停运汽前泵。4、 检查RB保护动作正常,否则手动执行RB程序:跳闸C、E磨煤机,电泵启动成功,控制负荷小于420MW,总煤量小于225t/h;如电泵启动不成功,控制负荷300MW,总煤量160t/h。5、 调整水煤比,控制汽水分离器出口蒸汽过热度在2-6之间,控制主、再热汽温不超限。6、 一台汽泵跳闸,电泵不能投入,负荷限在300MW以下;两汽泵跳闸,电泵单独运行,负荷限在180MW以下。7、 若两台汽泵跳闸,电泵不能投入,给水流量低锅炉MFT,按MFT动作处理。8、 若汽泵跳闸后出口电动门、中间抽头电动门未关严,立即就地手动摇关,保持入口电动门、最小流量阀开启。9、 若汽泵倒转,处理无效,立即将运行给水泵打闸,锅炉MFT,关闭锅炉上水电动门。10、 事故处理过程中注意加强给水流量、中间点温度、主、再热汽温、受热面壁温、除氧器水位等参数的监视、调整。凝泵跳闸处理措施1、 确认运行凝泵跳闸,备用泵联启成功,否则手启。2、 备用泵启动后,检查跳闸泵出口门联关,关闭除氧器上水旁路电动门,调整除氧器水位在2500mm左右。3、 如跳闸泵倒转,立即手动摇紧出口电动门,同时就地振打逆止门,保持跳闸泵的入口电动门开启。4、 工频泵联启后,通知化学运行人员,加强凝结水精处理运行监视。5、 如除氧器水位大于2660mm时,检查除氧器至凝汽器溢流电动门联开;除氧器水位大于2810mm时,检查除氧器底部放水电动门联开,否则手动开启。6、 调整凝汽器补水调门控制凝汽器水位大于500mm,必要时启动凝输泵。7、 如备用泵联启不成功,允许强启一次跳闸泵。强启不成功,不允许再次启动,按凝结水中断处理。8、 凝结水中断后,立即手动跳闸上层磨煤机,机组甩负荷至180MW,设法在5分钟内恢复凝结水系统。9、 如除氧器水位低至760mm,运行给水泵跳闸,锅炉MFT。10、 事故处理中注意加强除氧器水位、温度、压力、给水泵密封水、低加水位、真空提高装置的监视、调整。循环水泵全停处理措施1、 两台循环水泵跳闸后,立即抢合循环水泵一次,抢合不成功不得再抢合。2、 循环水中断无法恢复,应立即锅炉MFT,检查汽机联跳、发电机解列。3、 启动高备泵、交流润滑油泵、顶轴油泵运行,切断所有进入凝汽器的热源。停运真空泵,开启真空破坏门。4、 关闭循环水至凝汽器进出水门、循泵蝶阀,对循环水母管保压。5、 汽机转速到零,投入盘车;真空到零,停止轴封供汽。6、 如盘车不能正常投运,对汽机进行闷缸,监视上下缸温差小于56。7、 维持凝结水泵运行,投入疏扩减温水及低压缸喷水降温,必要时对凝汽器补充冷除盐水,降低凝结水温度。8、 加强闭式水温监视,必要时换水降温。将空压机冷却水切至运行机组供水。9、 故障原因查清并消除后,待凝汽器排汽温度降到50以下,进行小流量通循环水。10、 事故处理中,加强汽轮机上下缸温差、排汽温度、润滑油温、凝结水温度、闭式水温等参数的监视、调整。闭式水泵全停处理措施1、 两台闭式水泵跳闸后,立即抢合闭式水泵一次,抢合不成功不得再抢合。2、 闭式水中断无法恢复,应立即锅炉MFT,检查汽机联跳、发电机解列。3、 启动高备泵、交流润滑油泵、顶轴油泵运行,切断所有进入凝汽器的热源。4、 将空压机冷却水切到运行机组供应。5、 主机转速降到2300rpm以下,停运真空泵,开启真空破坏门。6、 汽机转速到零,投入盘车;真空到零,停止轴封供汽。记录转子惰走时间、偏心度、盘车电机电流、缸温等。7、 降低变频凝泵转速,加强凝泵轴承温度监视,如无法维持运行,停运凝结水泵运行。8、 加强运行辅机轴承温度、润滑油温监视。停止送、引风机、等离子水泵、氢气干燥器。9、 凝结水泵停运后,给水泵密封水消失,将给水泵密封水回水倒至地沟。10、 加强定冷水系统监视,定子冷却水温高时及时进行换水,防止水温过高,使小混床失效。锅炉MFT处理措施1、立即手动停止未自动跳闸的一次风机、磨煤机、给煤机,关闭两台一次风机进口调节动叶。2、确认所有燃油快关阀、各供油阀关闭,过、再热器减温水电动门、调节门关闭。确认所有磨煤机热风隔离门、冷风隔离门、出口门、冷风调节门、热风调节门均关闭。3、进行跳闸后吹扫,即维持35%的风量对炉膛进行5min吹扫。经吹扫后方可停运送风机、引风机。4、检查主汽压力正常,当压力过高时可开启锅炉PCV阀进行泄压。5、检查螺旋水冷壁、垂直水冷壁的壁温和进出口工质温度应正常,必要时维持小流量(200t/h)进水,控制水冷壁的温度正常。6、退出电除尘、脱硫、脱硝运行。7、将未退出炉膛的吹灰器退出。8、从FSSS首显跳闸画面,查明MFT首出原因。9、若引、送风机全部跳闸,应强制自然通风15min后,才能启动风机进行锅炉点火前吹扫。10、及时消除故障,做好热态启动准备。如故障难以在短时间内消除,按常规停炉处理。给水流量突降或中断处理措施1、 给水泵故障,备用给水泵未能投运时,立即手动启动备用给水泵。2、 有关阀门被误关时,应设法手动开启。3、 给水自动装置不正常时,应手动维持给水流量,维持正常水煤比4、 主汽压过高导致给水降低时,通过减少燃料量或开大调门降低主汽压力,增大给水流量。5、 当给水流量402t/h时,应紧急减少燃料量,使燃料量与给水流量相适应,并检查风量自动