设计计算一 确定尺寸及桩个数:设计采用C20的混凝土,桩径d=1.00m,挖孔灌注桩,桩长l=41.00m,伸入持力层(粗纱)的深度为3.3m。 求:根据条件,所选公式:可查知持力层的基本承载力查规范得则桩底地基土的容许承载力: 求:公式:查规范得查规范得(钻孔灌注桩极限摩阻力)。;。则: 定桩数:取u=1.5则:布桩如下:二 计算: 桩的计算宽度bo:公式: 求变形系数: 假设为弹性桩,则: 则得: 计算: 查规范得因而取,所以 计算,因,所以查规范知: 则:三 计算承台位移:计算 ,; 计算,;地面以下承台计算宽度: 计算情况一:双孔重载;情况二:一孔重载;四墩顶位移检算:将墩身作如图划分; 1墩帽所受风力:托盘所受风力:托盘如下图;则:墩身四个部分每个部分所受风力:H3= H4 =H5= H6由所得风力(水平),及墩顶荷载,得各截面弯矩,列表如下:位置荷载2(KN.m)3(KN.m)4(KN.m)5(KN.m)6(KN.m)水平位移911.7KN2461.593947.665433.736991.88405.87墩帽风力9.6KN20.1635.8151.4667.1082.75托盘风力9.66KN7.6523.4039.1454.8970.63墩身风力4.1728KN3.4010.2017.0023.814.1728KN3.4010.2017.004.1728KN3.4010.204.1728KN3.40墩顶弯矩总计7899.409420.2710947.9312482.3914023.662计算墩顶的水平位移根据列表如下:2-38659.401.630.8157.65316.5308.549×10-50.697×10-43-410184.101.632.4458.33317.9999.222×10-52.255×10-44-511715.161.634.0758.94919.3209.915×10-54.040×10-45-613253.031.635.7059.70220.95610.308×10-55.881×10-4总计3.799×10-41.287×10-3五单桩承载力验算:六群桩承载力验算: 七桩在上面处的位移检算:八桩身截面配筋:1Mz计算表:按要求只验算一孔重载情况:则:系数的值根据从基础工程表611查得并计算列表如下: 桩身弯矩表aZZAmBm-22.7Am202.1BmMz0.0 0.000 010.000 202.100 202.100 0.1 0.244 0.11-2.270 202.100 199.830 0.2 0.488 0.1970.998-4.472 201.696 197.224 0.3 0.732 0.290.994-6.583 200.887 194.304 0.4 0.976 0.3770.986-8.558 199.271 190.713 0.5 1.220 0.4580.975-10.397 197.048 186.651 0.6 1.463 0.5290.959-12.008 193.814 181.806 0.7 1.707 0.5920.938-13.438 189.570 176.131 0.8 1.951 0.6460.913-14.664 184.517 169.853 0.9 2.195 0.6890.884-15.640 178.656 163.016 1.0 2.439 0.7230.851-16.412 171.987 155.575 1.1 2.683 0.7470.814-16.957 164.509 147.553 1.2 2.927 0.7620.774-17.297 156.425 139.128 1.3 3.171 0.7680.732-17.434 147.937 130.504 1.4 3.415 0.7650.687-17.366 138.843 121.477 1.5 3.659 0.7550.641-17.139 129.546 112.408 1.6 3.902 0.7370.594-16.730 120.047 103.318 1.7 4.146 0.7140.546-16.208 110.347 94.139 1.8 4.390 0.6850.499-15.550 100.848 85.298 1.9 4.634 0.6510.452-14.778 91.349 76.572 2.0 4.878 0.6140.407-13.938 82.255 68.317 2.2 5.366 0.5320.32-12.076 64.672 52.596 2.4 5.854 0.4430.243-10.056 49.110 39.054 2.6 6.341 0.3550.175-8.059 35.368 27.309 2.8 6.829 0.270.12-6.129 24.252 18.123 3.0 7.317 0.1930.076-4.381 15.360 10.979 3.5 8.537 0.0510.014-1.158 2.829 1.672 4.0 9.756 000.000 0.000 0.000 弯矩图:2截面的配筋;根据桥规规定,取0.5% 则采用22的光面钢筋则:所以取=16则取钢筋的净保护层厚度为80mm。则钢筋的净间距为:钢筋布置如图所示:取主筋的长度为取箍筋有弯矩的上10m采用8200下面2m采用8400钢筋与承台的联结方式;采用主筋伸入式。桩身进入承台0.12m。主筋伸入承台板1m。因钢筋的长度超过4m,所以需要配置骨架钢筋,骨架钢筋采用182000定位钢筋采用182000九有关验算:1求偏心矩; 由表可知, 2判别大小偏心;属于大偏心受压构件。3.截面应力检算;荷载偏心率为:经试算:取查结构设计原理表3-3得:应力满足强度要求。4.稳定性验算;由结构设计原理表3-2得=1.0表3-1得m=18.6稳定性满足要求。5.裂缝验算;取r=1.2抗裂性满足要求。