欢迎来到三一办公! | 帮助中心 三一办公31ppt.com(应用文档模板下载平台)
三一办公
全部分类
  • 办公文档>
  • PPT模板>
  • 建筑/施工/环境>
  • 毕业设计>
  • 工程图纸>
  • 教育教学>
  • 素材源码>
  • 生活休闲>
  • 临时分类>
  • ImageVerifierCode 换一换
    首页 三一办公 > 资源分类 > DOC文档下载  

    钢塔和钢管杆基础的评估和修理毕业论文外文翻译.doc

    • 资源ID:3994775       资源大小:119.50KB        全文页数:20页
    • 资源格式: DOC        下载积分:8金币
    快捷下载 游客一键下载
    会员登录下载
    三方登录下载: 微信开放平台登录 QQ登录  
    下载资源需要8金币
    邮箱/手机:
    温馨提示:
    用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)
    支付方式: 支付宝    微信支付   
    验证码:   换一换

    加入VIP免费专享
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    钢塔和钢管杆基础的评估和修理毕业论文外文翻译.doc

    Assessment and Repair of Steel Tower & Steel Pole FoundationsNelson G. Bingel III¹ and Kevin D. Niles²¹Osmose Utilities Services, Inc., 215 Greencastle Rd., Tyrone, GA 30290-2944; PH(770) 632-6703; email: nbingel²Osmose Utilities Services Inc., 980 Ellicott St., Buffalo, NY 14094-2398; PH (716)319- 3404; email: knilesAbstractDuring the course of their service-life steel pole and lattice tower foundations aresubjected to significant environmental forces that can have a detrimental impact ontheir service life. Foundations are critical components of all transmission systems and therefore are crucial to the national power grid.Deterioration identified in these foundations during regular inspections and assessment should be categorized into specific levels of structural severity. Each should be addressed accordingly by a varied regimen of mitigation and repair options.Coatings and anode installation are most commonly used to help prevent deterioration. Repair options include but are not limited to: bolted steel repairs, welded steel repairs, reinforced concrete encasement of concrete foundations anddirect member replacement.This paper will address assessment and repairs specific to steel tower and steel pole foundations inclusive of structural durability, corrosion issues and standard repairmethods.Steel Transmission StructuresRegardless of their construction, steel transmission structures are composed of two basic components: the foundation which provides basic structural support for the entire structure and the structure itself, which creates clearance and provides support to the overhead electric conductors, ground wires and their associated hardware. Most steel transmission structures can be separated in to five distinct groups:Self Supporting Steel Lattice Towers which are typically constructed bymechanically joining multiple steel members together to form a supporting lattice space truss.Guyed Steel Lattice Towers similar to the self supporting steel lattice structures described above, guyed towers are distinctly different because of their reliance onmultiple guys to provide structural stability. Self-Supporting Steel Poles which are usually constructed of only a few large components welded together to form a tapered hollow “pole”. Guyed Steel Poles similar to self-supporting steel poles, guyed steel poles rely on multiple guy wires to provide stability. Tubular Steel H-Frames consisting of two steel poles placed adjacent to ach other with a steel cross arm spanning the distance between the two.Foundation TypesAll steel structure types require an adequate foundation to support the loads imposed on the structure. Because of the varying types of environments and soil conditions where these structures may be located, it is necessary to utilize different types of foundations in order to provide a stable platform for the structure. These include:Direct-embedment, which can be utilized for both steel poles and steel grillage, involves the excavation of a foundation hole in the earth by means of a drill rig or similar equipment. Excavations are made to accommodate the tower leg and grillage, which are set into the excavation and backfilled with either native soil, compacted gravel, crushed stone or concrete.Direct embedment of steel poles and steel grillages may sometimes be preferred over other foundation options due to their typically lower cost and ease of installation. However, they are usually not used where shallow rock and ledge are present or in areas where soil stability is a concern due to sandy soil conditions or in soil weakened by the influence of water. Concrete foundations can encompass a wide range of variations depending on the application they are being utilized for. Two of the most common types are: Drilled shafts also called caissons, which are probably the most widely used concrete foundation type. These foundations are installed by drilling holes with a large auger and then filling them with concrete and reinforcing steel. In some cases a “belled” drill shaft is used instead of a straight shaft to help provide additional capacity. A belled hole is created in the same way as a regular drilled shaft but with a distinct modification. The bottom portion of the hole is hollowed out creating a type of anchor or “bell” at its base. Pier slabs (pads) encompass a wide range of applications and can either be pre-cast or formed and poured in place. Typically, these foundations are relatively shallow in comparison to drilled foundations, with most set at an average depth of approximately 10 or less. This usually entails the excavation of large foundation holes and a significant amount of non-native backfill which is compacted in place over the foundations. These foundations rely on their large surface area and weight of backfill to provide stable support for the structure and resistance to uplift. One of the most significant advantages of reinforced concrete foundations is that thestructural steel members are protected from the environment by the concrete, whichlimits their exposure to corrosion and significantly increases their service life.Base Plates, Anchor Bolts and Stub AnglesWhen utilizing drilled shaft or pier slab foundations it is necessary to have a reliableinterface connection between the steel and concrete.Three of the most common connections are Base Plate and Anchor Bolts Lattice towers and steel poles have used both base plates and anchors bolts of various designs to anchor the upper support structure to the foundation. Stub Angles usually a short piece of angle steel with shear connectors,which is set directly into the concrete. Pin Bases several designs have been engineered to create a pin connection between a tower and its foundations. These are normally used with guyed structures such as guyed vees.Reasons to InspectIt is important to understand that with all structures there is a need for periodicinspection to ensure structural integrity and public safety. Steel structures and theirfoundations are no exception, as these structures are sometimes placed inenvironments that are less than ideal relative to the longevity of their structuralcomponents.Environmental conditions can have a dramatic impact on the structural integrity of steel and concrete over relatively short periods of time. Detrimental influences suchas agricultural activity, changes in soil elevation from construction and emissionsfrom manufacturing facilities can all contribute to the degradation of structural components. These effects can be compounded by unseen defects in structuralmembers, coatings and concrete at the time of construction.Often these environmental influences combine to create active corrosion cells which are detrimental to steel structural components.Definition of a Corrosion CellThe basic electrochemical corrosion cell consists of four components; a cathode, ananode, an electrolyte and a metallic path. Corrosion within the cell exists because ofthe flow of electrons and ions between these components. Anode the point where corrosion takes place within the cell due to the flow of positively charged ions away from it. Cathode negatively charged ions migrate from the cathode, which creates a polarization helping to protect the cathode from corrosion.Electrolyte is a substance or solution capable of conducting electricity.Metallic path conducts negatively charged electrons from the anode to thecathode.With a corrosion cell on steel towers and steel poles, the electrolyte is represented by the soil the structure is buried in. The metallic path is the metal of the structure andthe cathode and anode can either be between the different legs of a steel tower oralong the surface of a steel pole where there is a difference of corrosion potential between two points.Development of Corrosion InspectionSome of the earliest studies into corrosion took place in England during the mid tolate 1800s, with additional detailed testing to come in the early 1900s. This early research into the chemistry of corrosion developed the fundamentals of research and inspection that are still in use today.Mainly used in gas, petroleum and other similar industries, corrosion inspection is a proven science with a long history of success. Inspection procedures and equipment have been developed and refined over many years, even though some of their basic principles have not changed.In recent years, inspection methods and mitigation technology have been adopted bymany other industries, both public and private, which have an economic interest in protecting their infrastructure. Electric utilities are no exception and have begun to recognize the necessity for integrating corrosion inspection and mitigation efforts intotheir regular maintenance programs.Direct Inspection ProceduresA large majority of corrosion inspection is conducted through visual and physical assessment. These inspection methods include: Visual assessment by utilizing various grading criteria from recognized experts in the industry, corrosion on metal can be quantified by various grades. A standard method for this purpose is the “SSPC VIS2 Standard Method for Evaluating Degree of Rusting on Painted Steel Surfaces”,developed by the Society for Protective coatings. This allows the inspector to compare existing surface corrosion to samples in the standard so the corrosion can be classified by both type and severity. Physical measurements allow the inspector to measure the different components of a structure to help determine the amount of section loss cause by corrosion. The most common hand devices for these measurements are calipers, micrometers and pit gauges. Photos are sometimes also used to support the physical measurements recorded in the field. Excavation because steel towers and steel poles may be buried in soil it is often necessary to make shallow inspection holes. The excavation extends the visual assessment and physical measurements through the initial transition area of the steel to soil interface. Usually inspection excavations are limited to a depth of 18” 24” but can occasionally be deeper if necessary to determine the extent of visible corrosion. Ultrasound measurements when visual inspection and physical measurements are limited due to a structures design or location, ultrasoundcan be successfully utilized in certain applications to help further assess a structures condition. Electromagnetic Acoustic Transducer (EMAT) technology has expanded the use of ultrasonic testing from rudimentary lateral scans reading through the structure to longitudinal scans along the length of its surface. This process can detect below ground corrosion on steel structures.Indirect Inspection MethodsEnvironmental factors have a significant affect on the corrosion process. Indirect inspection methods have been developed to quantify their influence at specific locations. Several of these methods have become standard procedures in the pipeline industry and have been adapted for use in evaluating the environmental conditions surrounding steel structures.pH probably one of the most easily understood environmental influences, the pH measurement of soil surrounding a tower determines how acidic the soil is and helps to define its potential influence in the corrosion process. Measurements of a pH around 7 show a relatively neutral environment while measurements of 5.5 or less are considered to be acidic. A pH reading of 8.0 or more usually indicates an alkaline environment and is typically less of a concern as it usually has little corrosive effect on steel. Redox otherwise known as the measurement of oxygen reduction, redox measures the dissolved oxygen content in the soil. Distinct differences in oxygen content in the soil surrounding a buried steel structure can indicate the potential influence of microbial activity on corrosion.Although bacteria itself does not typically attack metals directly, variobacteria develop in certain Redox environments which can influence the corrosion process by creating corrosive byproducts. Environments free of oxygen support the presence of anaerobic bacteria, while oxygen rich environments tend to support aerobic bacteria. Environments that exist somewhere in the middle of the scale are relatively neutral and tend not to support microbial activity detrimental to steel. Redox measurements collectedin close proximity to the structure can help to determine whether a structure is at risk from microbial influence. Redox measurements of less than 100 mV can indicate the presence of aerobicbacteria and an increased potential for corrosion activity. While redox measurements between 100 and 350 mV which tend to support moreanaerobic activity tend to be more neutral.Soil Resistivity - is a significant indicator in determining how corrosive a soilenvironment is. Soils with low resistivity allow for the easy flow of currentbetween an anode and cathode creating a higher level of corrosion activity. Soils with a resistivity of 1000 ohm-cm or less tend to be very corrosive, while soils with a resistivity of 10,000 ohm-cm are considered much less of aninfluence to corrosion.Half Cell Measurements measure the structure to soil potential within theenvironment. Typically, this is done utilizing a digital or analog potentialmeter. The more negative the measurement is (< -.850 mV), the more likely itis that the structure will have a reduced potential for corrosion. The less negative the measurement (> -.400 mV), the more likely it is to corrode.Corrosion RatingThe factors previously discussed are only indicative when considered alone. They must be evaluated as to how they relate to each other in a specific environment. To dothis an algorithm was developed to measure these factors together in order todetermine a structures potential for corrosion or its “corrosion rating”. These ratings are divided into specific categories quantifying each structurespotential for future corrosion, as listed below: Low the potential for corrosion is low and no further action is necessary at this time. Typically the recommendation for these structures is to re-inspect in another ten years. Mild the potential for corrosion is slightly elevated and, while it may not be visually evident, it is possible that minor corrosion activity is present. Similar to the structures rated as low, it is recommended to re-inspect these structures in another ten yearsModerate structures rated as moderate usually show positive indicating factors for corrosion even though only minor corrosion may currently be visible. This corrosion may appear as minor surface corrosion or pitting. Structures in this condition should have mitigation efforts put in place soon to help avoid further c

    注意事项

    本文(钢塔和钢管杆基础的评估和修理毕业论文外文翻译.doc)为本站会员(文库蛋蛋多)主动上传,三一办公仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知三一办公(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    备案号:宁ICP备20000045号-2

    经营许可证:宁B2-20210002

    宁公网安备 64010402000987号

    三一办公
    收起
    展开