欢迎来到三一办公! | 帮助中心 三一办公31ppt.com(应用文档模板下载平台)
三一办公
全部分类
  • 办公文档>
  • PPT模板>
  • 建筑/施工/环境>
  • 毕业设计>
  • 工程图纸>
  • 教育教学>
  • 素材源码>
  • 生活休闲>
  • 临时分类>
  • ImageVerifierCode 换一换
    首页 三一办公 > 资源分类 > DOC文档下载  

    全国职称英语 理工类 完形填空小抄版.doc

    • 资源ID:2323149       资源大小:22.50KB        全文页数:2页
    • 资源格式: DOC        下载积分:8金币
    快捷下载 游客一键下载
    会员登录下载
    三方登录下载: 微信开放平台登录 QQ登录  
    下载资源需要8金币
    邮箱/手机:
    温馨提示:
    用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)
    支付方式: 支付宝    微信支付   
    验证码:   换一换

    加入VIP免费专享
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    全国职称英语 理工类 完形填空小抄版.doc

    Better Solar Energy Systems: More Heat, More LightSolar photovoltaic thermal energy systems, or PVTs, generate both heat and electricity, but until now they havent been very good at the heat-generating part compared to a stand-alone solar thermal collector. Thats because they operate at low temperatures to cool crystalline silicon solar cells, which lets the silicon generate more electricity but isnt a very efficient way to gather heat.Thats a problem of economics. Good solar hot-water systems can harvest much more energy than a solar-electric system at a substantially lower cost. And it,s also a space problem:photovoltaic cells can take up all the space on the roof, leaving little room for thermal applications.In a pair of studies, Joshua Pearce, an associate professor of materials science and engineering, has devised a solution in the form of a better PVT made with a different kind of silicon. His research collaborators are Kunal Girotra from ThinSilicon in California and Michael Pathak and Stephen Harrison from Queens University, Canada."Most solar panels are made with crystalline silicon,but you can also make solar cells out of amorphous silicon, commonly known as thin-film silicon. They dont create as much electricity, but they are lighter, flexible, and cheaper. And, because they require much less silicon, they have a greener footprint. Unfortunately,thin-film silicon solar cells are vulnerable to some bad-news physics in the form of the Staebler-Wronski effect.“That means that their efficiency drops when you expose them to light pretty much the worst possible effect for a solar cell,” Pearce explains,which is one of the reasons thin- film solar panels make up only a small fraction of the market.However, Pearce and his team found a way to engineer around the Staebler-Wronski effect by incorporating thin-film silicon in a new type of PVT. You dont have to cool down thin-film silicon to make it work. In fact,Pearces group discovered that by heating it to solar-thermal operating temperatures,near the boiling point of water, they could make thicker cells that largely overcame the Staebler-Wronski effect. When they applied the thin-film silicon directly to a solar thermal energy collector , they also found that by baking the cell once a day,they boosted the solar cells electrical efficiency by over 10 percent.“Liquefaction” Key to Much of Japanese Earthquake DamageThe massive subduction zone1 earthquake in Japan caused a significant level of soil"liquefaction"2 that has surprised researchers with its  widespread severity, a new analysis shows."We've seen localized3 examples of soil liquefaction as extreme as this before, but the distance and  extent of damage in Japan were unusually severe," said Scott Ashford, a professor of geotechnical engineering4 at Oregon State University5. "Entire structures were tilted and sinking into the sediments," Ashford said. "The shifts in soil destroyed water, drain and gas pipelines6, crippling the utilities and infrastructure these communities need to  function . We saw some places that sank as much as four feet."Some degree of soil liquefaction7 is common in almost any major earthquake. It's a phenomenon in which soils soaked with water, particularly recent sediments or sand, can lose much of their  strength  and flow during an earthquake. This can allow structures to shift or sink or  collapse .    But most earthquakes are much  shorter than the recent event in Japan, Ashford said. The length of the Japanese earthquake, as much as five minutes, may force researchers to reconsider the extent of liquefaction damage possibly occurring in situations such as this8."With such a long-lasting earthquake, we saw  how structures that might have been okay after 30 seconds just continued to sink and tilt as the shaking continued for several more minutes," he said. "And it was clear that younger sediments, and especially areas built on recently filled ground, are much more vulnerable."The data provided by analyzing the Japanese earthquake, researchers said, should make it possible to improve the understanding of this soil  phenomenon  and better prepare for it in the future. Ashford said it was critical for the team to collect the information quickly, before damage was removed in the recovery efforts9."There's no doubt that we'll learn things from what happened in Japan10 that11 will help us to reduce risks in other similar  events ," Ashford said. "Future construction in some places may make more use of techniques known to reduce liquefaction, such as better compaction to make soils dense, or use of reinforcing stone columns."Ashford pointed out that northern California have younger soils vulnerable to liquefaction -on the coast, near river deposits or in areas with filled ground. The "young" sediments, in geologic terms, may be those deposited within the past 10,000 years or more. In Oregon, for instance, that describes much of downtown Portland, the Portland International Airport and other cities.Anything  near a river and old flood plains is a suspect12, and the Oregon Department of Transportation has already concluded that 1,100 bridges in the state are at risk from an earthquake. Fewer than 15 percent of them have been reinforced to prevent collapse. Japan has suffered tremendous losses in the March 11 earthquake, but Japanese construction standards helped prevent many buildings from collapse -even as they tilted and sank into the ground.待添加的隐藏文字内容3

    注意事项

    本文(全国职称英语 理工类 完形填空小抄版.doc)为本站会员(仙人指路1688)主动上传,三一办公仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知三一办公(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    备案号:宁ICP备20000045号-2

    经营许可证:宁B2-20210002

    宁公网安备 64010402000987号

    三一办公
    收起
    展开