Super Therm - Arizona Superior Coatings.ppt
Super Therm,By:Jim WilliamsPresidentArizona Superior CoatingsP.O.Box 385Vail,AZ85641(520)647-,SUPER THERMSP SEAL COATHSC 1000(hot surface coat)iSTUCCO SYSTEM,What is Super Therm?,SUPER THERMThermal Barrier Ceramic Coating,SUPER THERM is a ceramic based,water borne,thermal barrier coating that is designed to block and reflect heat that increases energy and maintenance cost.As the only ceramic coating developed in cooperation with NASA,SUPER THERM is the most effective,durable,and long lasting ceramic coating on the market.,What makes Super Therm Unique?,30%,Average Energy Savings,It has 4 unique ceramic compounds which:Block 95%of Solar Heat Insulate,What kind of heat does Super Therm block?,Heat Sources from the Sun,How much heat does Super Therm block?,99.5%Infrared,99%Ultraviolet,92%Visible Light,Properties of Cool Roofing Materials Definitions,Solar ReflectivityAmount of incoming solar energy a material reflects(usually in%)EmissivityAmount of energy a material emits due to its own heat and temperature(usually in%),roof,sun,reflected,emitted,Fear of glare Super Therm produces diffused reflections,not secular reflections,14,Nippon Paint Factory Roof Insulation,Heat Loss Captured by Infrared Camera BEFORE Application of Super Therm,15,Residential HomeLittle Rock,Arkansas,Heat Loss Captured by Infrared Camera AFTER Application of Super Therm,Why Super Therm is preferred over other products?,UNIQUE CERAMIC COMPOSITION,Blend of four different ceramics that block all windows of heat transfer.Other ceramic coatings only contain glass hollow spheres that reflect visual light when clean but absorb and transfer other windows of heat.Only ceramic coating rated as an insulator by BOCA(Us Building Code).Includes various resins,including urethanes for durability and longevity.,Rain,Moisture,Humidity,Protection from the elements,Dampens sound waves,Super Therm,68%reduction,Super Therm is rated as a true insulator by BOCA(US Building Code),R19 equivalent rating,Super Therm,=,6”8”,10 mil dry,ASHRAE 90.1 CODE COMLIANCE,TESTING REQUIRED TO PROVE THE RE VALUEA.ASTM C 236-89“Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box.”B.ASTM 1269“Differential Scanning Calorimeter”ASTM E 1461-92“Thermal Diffusivity.”Super Therm has a“U”(Thermal Flow)Value of 0.052.Super Therm is(1/RE)=0.052 Thermal Flow.ASHRAE 90.1 Compliance Varrience cannot exceed 0.061 for Thermal Flow.Super Therm falls within the ASHRAE 90.1 Compliance Rating and is acceptable.,Class A Fire Rating,Super Therm,Prevents Mold and Mildew,USDA Approved,Certified Water Barrier(ASTM D 7088,ASTM D 6904),Super Therm,Environmentally Friendly(24 grams per liter VOC),Very Long Life Expectancy,20 Years,Extraordinary elasticity,Passed ASTM E1737,Where can Super Therm be used?,Roof Insulation,Topside,Underside,Concrete Insulation,walls,floors,Sound proofing,Ice Machines,Elevators,Building Envelope,Air Conditioning&Ducting,AC Units,AC Ducting,Companies that have used Super Therm,Customers who have used Super Therm,39,Before Super Therm Application Saw Tooth Section Built 1937,After Super Therm Application,187,000 Sq.Ft.of Metal and 82,000 Sq.Ft.of Tar&Gravel,Chicago Bridge&Iron CompanyBeaumont,Texas,40,Nissan Motor Co.Ltd.Yokahama,Japan200,000 Sq.Meters,Before,After,Tucson Intl.Airport Tucson,AZ,Super Therm was applied toCentral PlantWest ConcourseEast ConcourseWash BaysNote:A power wash and thorough cleaning was performed on all roof tops prior to application,Tucson International Airport,August 2009 Savings=$22,144,Chris Wilt-Senior Director Facility Development,RESIDENTIAL HOME TUCSON,AZ,Super Therm was applied toRoof TopFront Porch CoverBack Patio CoverSP Seal Coat was used on all water channels and cricketsAll penetrations were sealed prior to Super Therm,70 degrees,77 degrees,BEFORE CIRCLE K TUSCON,AZ,AFTER CIRCLE K TUCSON,AZ,TRUMP INTERNATIONAL FT.LAUDERDALE,FL,Super Therm was applied toConcrete ceiling of lobbyConcrete ceiling of parking structure under air conditioned space,SANTA ROSA DUNES PENSACOLA,FL,48,Bel-Air Condos in Austin,TexasSPI iStucco System,Thermal Scan BEFORE iStucco System,Thermal Scan AFTER iStucco System,iSTUCCO System Before,Ceramic Stucco Application,iStucco After Super Therm,Frito Lay Trailer,KY Trailer,Irvington Elementary School,KY,55,Apartent Buildings And HotelIn Munich Germany,56,Residential HomeLas Vegas,Nevada,Testing,Certification and Endorsements of Super Therm,Approved and accepted with Energy Star for saving energy.ASTM E 903-96 Reflectivity=80%Only 1%Reduction in Reflectivity over 3 Years(3%over 10 years),ENERGY STAR Program,B 117/D 1654 450 Hour Salt Spray(Fog)PassedC 177 thermal conductivity testing PassedC 236(C236-89(1993)el)Passed,our performed fiberglass by 148%.Standard Test Method for Steady-State Thermal Performance of Building Assemblies by means of Guarded Hot Box.Testing for measuring R-values.C 411 High Temperature Surface Performance PassedD 412 Tensile strength Passed.041 thickness=13,248 psi,ASTM Testing,ASTM Testing contd,D 522 PassedResistance to cracking on metal or rubber type materials.1”(25mm)bend.”(96mm)bendD 1653 Water Vapor Permeability PassedD 1654 Salt spray(fog/weathering)Passed 2000 hoursD 3273-82T D 3274 PassedResistance to fungal growth or soil and dirt accumulation on paint film.Excellent(8 out of 9)D 4060 Abrasion Resistance PassedE 84 Flame Spread/Smoke Developed PassedClass“A”Rating(or Class“1”or Class“I”),ASTM Testing contd,E84-89a Flame spread/Smoke Developed Passed“0”developmentFlame Index“0”.Smoke Index“0”E96 water vapor transmission Passed less than.01E 96 water vapor transmission Passed less than.01E 903-96 Reflectance PassedE 119 Structural Steel Fire curve Passed 25 minutesE 1269 Thermal penetration through a substrate by differential scanning calorimeter Passed blocking 99%of heat BTU conduction TPRL,ASTM Testing contd,E 1461-92 Laser flash technique conductivity diffusivity PassedVTEC Laboratories review of test results Letter stating RE19TPRL lab test results show a bare metal plate allowing 367.20 BTU heat conduction.SUPER THERM coated on metal plate allowed only 3.99 BTU heat gain.A 99%reduction in heat transfer after applying only one coat of SUPER THERM on test plate.G53 exposure to UV,elevated temperature and humidity-Passed,ICC Approval(International Code Councel)0104,Passed ID#21-25Council that formally consolidates approvals for BOCA(Building Officials Code Administrators)Section 723.2 Exposed installations,Thermal insulationSection 723.3 Concealed installations,Thermal insulationSection 803.2 Classification,Interior finish1998 International Mechanical CodeSection 604.3 Coverings and Linings,Insulation,ICBO(International Conference of Building Officials),Passed ASTM E 84 For Flame SpreadPassed ASTM C 411 for High Temperature for Surface PerformancePassed ASTM C 177 for Thermal Conductivity(*SUPER THERM Specific),NASA,NHB 8060.1B/C Test 1 Flammability testing Passed“0”Burn,Class“A”rating PassedNHB 8060.1C,Test 7 Toxic Off gassing Passed“K”no Toxic off gassing Passed“K”Rating for toxicity PassedTests performed at Marshall Space Flight Center,Key Endorsements,USDAPassedEnvironmentally safe and safe for use around animalsApproved for incidental food contactLetter of Written Certification as Accepted by USDA from ManufacturerUnderwriters Laboratory Inc.ApprovedFactory Mutual ApprovalPassed-E-108 Flame Spread over pitched roofingTested and Approved for Roofing and all other ApplicationsCalifornia Cool Roof ProgramCalifornia Building Energy Efficiency StandardsFlorida Cool Roof Rebate ProgramState approval for energy rebate,Next Steps:,Call me directly:(520)647 7672Go to our website at:Fill out the questionnaire and we will get back to you,Arizona Superior Coatings LLC.Corporate Office/ApplicatorP.O.Box 385,Vail,AZ 85641Office 520-647-7672Sales Jim Williams,John Montano,Frank Tainatongo,Doug Alley:Superior Performance Coatings,Inc.Phone(520)647-7672Email:Website:,